PARAMETERS
TCL
1
Automatic reclosure time (0 = off)
Reclosing time after transit on PH1
ttr
2
(0 = off)
Sensitivity on obstacles
SEI
3
0 = Maximum impact force
10 = Minimum impact force
Motor speed during opening
1 = minimum
2 = low
SFO
4
3 = medium
4 = high
5 = maximum
Motor speed during opening deceleration phase
1 = minimum *
2 = low *
SSO
5
3 = medium
4 = high
5 = maximum
Motor speed during closing
1 = minimum
2 = low
SFC
6
3 = medium
4 = high
5 = maximum
Motor speed during closing deceleration phase
1 = minimum *
2 = low *
SSC
7
3 = medium
4 = high
5 = maximum
STEP BY STEP or SBS configuration:
0 = Normal (AP-ST-CH-ST-AP-ST...)
1 = Alternate STOP (AP-ST-CH-AP-ST-CH...)
SBS
8
2 = Alternate (AP-CH-AP-CH...)
3 = Apartment block – timer
4 = Apartment block with immediate reclosure
Deceleration distance
LSI
9
0 to 100 = Motor deceleration percentage during
opening and closure
Post blackout procedure
BlT
10
0 = No action, remains stationery
1 = Closure
Energy saving: enables photocell switch-off when gate
is closed
SBY
11
0= disabled
1= enabled
* = only for SUN4224/SC4224
** = for SUN4224/SC4224 min 15
DESCRIPTION
DEFAULT
MIN
0
0
0
0
3
0
4
1
1
1
4
1
1
1
0
0
20
0 **
0
0
0
0
EN
MAX
UNIT
900
s
30
s
10
5
5
5
5
4
100
%
1
s
1
25