SAFETY AND CONTROL DEVICE CONNECTOR
COM
Common for the FLASH-IND-LED inputs
FLASH
Flashing light output 24Vdc (without regulation), maximum 25W
IND output for gate open indicator light 24 Vdc not regulated 4W MAX / Electric lock output 12Vac, 15VA maximum
IND
selectable with parameter
Courtesy light output 24Vdc (without regulation), maximum 25W, controllable also via radio ON-OFF command (radio
LED
channel 4 selecting fC.y. = 2, tC.y. = 0)
24 VAC
Accessories power supply 24 Vac without regulation, 200 mA (with battery operation output not active)
24 VAC
Accessories power supply 24 Vac without regulation, 200 mA (with battery operation output not active)
NEG
Accessories power supply negative
PH-POW
Photocells PH1 and PH2 power supply positive; phototest can be selected with parameter
STOP safety device, NC contact between STOP and STOP (warning, with dip switch 1 ON the safety device input is
off). This input is classified as a safety device; the contact can be deactivated at any time, cutting out the automation
STOP
system and disabling all functions, including Automatic Closure.
Safety sensor edge, ON/OFF, NC contact or resistive 8K2 between STOP and STOP.
Input selectable with parameter
Photocells (opening), NC contact between PH2 and COM (warning, with dip switch 2 ON the PHOTOCELL 2 safety
device input is off). The photocell is tripped at any time during opening of the automation system, halting operation
PH2
immediately; the automation system will continue opening when the contact is restored. In the event of intervention on
closure (parameter
Photocells (closing), NC contact between PH1 and COM (warning, with dip switch 3 ON the PHOTOCELL 1 safety
PH1
device input is off) The photocell is tripped at any time during closing of the automation system, halting operation im-
mediately and reversing the travel direction.
OPEN command NO contact between OPEN and COM
OPEN
Contact for the HOLD-TO-RUN function. The gate OPENS as long as the contact is held down
CLOSE command NO contact between CLOSE and COM
CLOSE
Contact for the HOLD-TO-RUN function. The gate CLOSES as long as the contact is held down
PEDESTRIAN command NO contact between PED and COM
PED
Used to open the gate partially, depending on the software setting (not active in barrier/up-and-over mode)
STEPPING command NO contact between SBS and COM
SBS
Open/Stop/Close/Stop command, or as set in the software
COM
Common for the PH2-PH1-OPEN-CLOSE-PED-SBS inputs
SHIELD
Antenna - shield -
ANT
Antenna - signal -
4.2 - Display during normal operation
In "NORMAL OPERATING MODE", i.e. when the system is powered up normally, the 3-figure LCD display shows the following status messages:
MESSAGES
MEANING
--
Gate closed or switch-on after shutdown
OP
Gate opening
CL
Gate closing
SO
Gate stopped during opening
SC
Gate stopped during closure
F1
Photocell 1 tripped
F2
Photocell 2 tripped
HA
Gate stopped by external event
ALI
Re-alignment procedure
oP
Gate stopped without automatic reclosure
OPD
Gate in pedestrian opening mode
Pe
Gate in pedestrian opening position without automatic reclosure
Gate open with timed reclosure
-tC
Flashing dash counting in progress
Dash replaced by figures 0..9 countdown (last 10s)
Gate in pedestrian opening position with timed reclosure
-tP
Flashing dash counting in progress
Dash replaced by figures 0..9 countdown (last 10s)
Learning started on limit switch (move the gate off the limit switch to continue the learning procedure) or lear-
L--
ning stopped due to trip of safety device or motor inversion.
LOP
Learning opening
LCL
Learning closure
In addition, the dots between the figures illustrate the status of the limit switches, as described in greater detail below:
MESSAGES
MEANING
-.-
Limit switch CLOSED (one dot between the two lines)
tC.
Limit switch OPEN (a point to the right)
SO
No limit switch active (no dots present)
IN.D.
n
Ed.m.
Ph.2.
= 0) the device stops and on release re-opens.
EN
24 Vdc, 250 mA
tp.h.
21