temperature will increase or decrease by one degree. The display shows the
value set. The temperature can be set to between 16 and 31°C.
 If you wish to dehumidify, press the function selector button until the 'dehum'
light comes on. Check that the water outlet hose is correctly connected, see
page 23! The temperature will be automatically set to 2 degrees below room
temperature (16°C to 31°C).
The fan speed will be automatically set to 'LOW'.
Caution: Because the temperature in the dehumidifier setting is set
automatically to 2 degrees below room temperature, the device will cool down
the room.
 Using the functions 'cooling' and 'dehumidifying', the apparatus will occasionally
stop in order to protect the compressor. The apparatus will restart after approx.
3 minutes. Do NOT change any settings in the meantime!
If you set the apparatus to 'cooling' or 'dehumidifying', it will continuously
operate unless:
- The room temperature becomes lower than the set temperature.
- The timer is set to a final time.
 If you wish to ventilate, use the function selector button to choose 'fan'; you
can then set fan speed to high or low using the fan speed button.
 The Timer button allows you to automatically start or stop the air conditioner
at a set time.
Automatic start:
First set at which temperature and in which mode (cooling, dehumidifying or
heating) you want the air conditioner to start.
Switch off the air conditioner using the <On/Off> button. Now the air conditioner
is in the stand-by position.
Press the <Timer> button.
Using the <Up> and <Down> buttons, set the number of hours after which the
air conditioner has to start (1-24 hours).
Press the <Timer> button once again. The displays of the air conditioner shows
the set number of hours.
The air conditioner will automatically start with the entered settings after the
lapsing of the set number of hours.
Automatic stop:
Press the <Timer> button while the air conditioner is operating.
Using the <Up> and <Down> buttons, set the number of hours after which the
air conditioner has to stop (1-24 hours).
Press the <Timer> button once again. The displays of the air conditioner shows
the set number of hours.
The air conditioner will automatically stop after the lapsing of the set number of
hours.