Water outlet
During the cooling process, the device removes water from the air. This largely
evaporates but any excess water is collected in the water reservoir. If the water
reservoir in the device is full, the compressor and
the motor will stop automatically and the 'water
tank full' light (W.F.) will come on. In this event,
switch the air conditioning unit off and remove the
plug from the socket. Empty the water tank by
removing the cap from the water drainage point
(see picture) and draining the tank into a drain or
receptacle. Do not forget to replace the cap again
afterwards! You can then switch the air
conditioning unit back on.
When dehumidifying, more water is removed from the air. This is why you must
connect a hose to the water drainage hose during dehumidifying and run this to a
drain (at a lower point).
Safety
The PAC 7.2 and PAC 9.2 are fitted with an overheating safeguard that switches the
unit off if it overheats. If this should occur, you must remove the plug from the
socket and leave the equipment to cool for at least 30 minutes. Remove the cause
of overheating - has the device been (partially) covered? Is it too close to a wall or
another obstacle, preventing it sucking in or dispelling sufficient air?
You can then use the device normally again but keep an eye on it for the first 30
minutes to ensure there are no further problems. If the device is showing signs of
problems or the overheating recurs, even though there is no obvious assignable
cause, ask your supplier or a recognised electrician to check/repair the unit.
Cleaning and maintenance
Note! Before cleaning or carrying out maintenance work on the air conditioning
unit, always switch off and remove the plug from the socket! Regular cleaning is
vital in order to keep the unit in good working order!
Cleaning the housing
Use a soft, damp cloth to wipe the housing.
Never use aggressive cleaning products, petrol, detergent, chemically-impregnated
cloths or other cleaning solutions. These could damage the housing. Never spray
the unit and ensure that water never penetrates the device! Dry the unit with a soft
cloth.