Application/use
▪ Use only original parts obtained from the manufacturer. The use of any non-original
parts releases the manufacturer from any liability.
▪ Collect any leakage of fluid and operating fluid immediately.
▪ Dispose of the operating fluid at certified collection points.
2.11
Operating fluid
There is an oil barrier chamber between the motor and the pump. The oil separation
chamber is filled with oil (lubricating oil in accordance with ISO VG Class 32). Small oil
leakages are not a cause for alarm, but should be cleaned up immediately. NO-
TICE! Large oil leaks indicate that the seal is broken. Contact customer service!
3
Application/use
3.1
Intended use
Submersible pumps are suitable for pumping:
▪ Sewage not containing faeces
– Wash basins
– Shower basins/bathtubs
– Washing machines
▪ Wastewater (with small amounts of sand and gravel)
– Rainwater
– Drainage water
Restricted use
NOTICE
For use inside buildings only
In accordance with EN 60335: Only use pumps with a connection cable under
10 m (33 ft) inside buildings. Do not use outdoors!
Pump type
Rexa MINI3-V04...-5M
Rexa MINI3-V04...-10M
Installation and operating instructions Wilo-Rexa MINI3
5 m (16,5 ft)
10 m (33 ft)
en
37