Troubleshooting - Clarke FOCUS II Micro Rider Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING

TROUBLE
The motors do not work; no warning light turns on.
The machine does not move and the display (71)
shows the error code:
At the machine start-up, the LED (64) of the
switch (63) lashes and the brushes do not work.
The brushes do not work; the red warning light
(62) lashes.
The 3 warning lights (62) lash simultaneously.
The display (71) shows the error code as:
where "00" is replaced by a code different from
"t4".
The dirty water vacuuming is insuficient.
The solution low is insuficient.
The squeegee leaves marks on the loor.
NOTE
If the machine has a battery charger installed, the machine cannot operate if the charger is not on board. In case of
battery charger malfunction, contact an authorized Clarke Service Center.
For further information, contact Clarke Service Centers.
7/11
INSTRUCTIONS FOR USE
POSSIBLE CAUSE
The battery connector is disconnected.
The batteries are discharged.
The machine has been turned on by using the
ignition key and by keeping the pedal pressed.
The machine has been turned off without
lifting the brush deck.
The batteries are discharged.
The brush motors are overloaded.
There are foreign materials (tangled threads,
etc.) preventing the brushes from rotating.
The machine electronic control system is in
alarm condition.
The recovery tank is full.
The vacuum grid is clogged or the loat is
closing.
The container with debris collection grid is
clogged.
The hose is disconnected from the squeegee. Connect.
The squeegee is dirty, or the squeegee blades
are worn or damaged.
The tank cover is not properly closed, or the
gasket is damaged.
The solution tank is empty.
The solution ilter is dirty.
The Chemical Mixing System tank (optional)
is dirty/clogged.
There is debris under the squeegee blades.
The squeegee blades are worn, chipped or
torn.
The squeegee pitch needs to be adjusted
9099236000 - FOCUS II Micro Rider
REMEDY
Connect.
Charge the batteries.
Release the drive pedal.
If the problem persists, contact an authorized
Service Center.
Before turning on again the brushes by
pressing the switch (63), wait till the deck is
lifted.
Charge the batteries.
Use less aggressive brushes and/or avoid
working with extra pressure turned on.
Clean the brush hubs.
Turn off the machine and then turn it on again.
If the problem persists, contact an authorized
Clarke Service Center.
Empty the tank.
Clean the vacuum grid.
Clean.
Clean the squeegee or turn over/replace the
blades.
Correctly close the cover or clean/replace the
gasket.
Reill.
Clean the ilter.
Clean with the drain cycle.
Remove the debris.
Turn over or replace the blades.
Adjust the squeegee.
ENGLISH