Venting Requirements - Whirlpool GXW7330DXS Instructions D'installation Et Guide D'utilisation Et D'entretien

Hotte de cuisinière configurée en îlot à montage mural 30" (76,2 cm) et 36" (91,4 cm)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cabinet Dimensions
7¹⁄₄" (18.4 cm)
6⁵⁄₈" (16.8 cm)
7³⁄₈" (18.8 cm)
Side
cabinet
30" (76.2 cm) or
36" (91.4 CM)
"X"
bottom of
canopy
to cooking
surface
*For non-vented (recirculating) installations
IMPORTANT:
Minimum distance "X": 24" (61.0 cm) from electric cooking
surface.
Minimum distance "X": 27" (68.6 cm) from gas cooking
surfaces.
Suggested maximum distance "X": 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights. See
the following chart.
Vented Installations
Min. ceiling height
Electric cooking
7' 5" (2.26 m)
surface
Gas cooking
7' 8" (2.34 m)
surface
Non-vented (recirculating) Installations
Min. ceiling height
Electric cooking
7' 5" (2.26 m)
surface
Gas cooking
7' 8" (2.34 m)
surface
*NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soffit heights depending on the
distance "X" between the bottom of the range hood and the
cooking surface. For higher ceilings, a Stainless Steel Chimney
Extension Kit Part Number W10337357 is available from your
dealer or an authorized parts distributor. The chimney
extension replaces the upper chimney shipped with the
range hood.
2" (5.1 cm) min.
6" (15.2 cm) min.*
Vent and power
supply cable
entry location
15" (38.1 cm)
Side
cabinet
Centerline
Cooking surface
Max. ceiling height
9' 2" (2.79 m)
9' 2" (2.79 m)
Max. ceiling height
9' 6" (2.9 m)
9' 6" (2.9 m)

Venting Requirements

(vented models only)
■ V ent system must terminate to the outdoors, except for non-
vented (recirculating) installations.
■ D o not terminate the vent system in an attic or other
enclosed area.
■ D o not use 4" (10.2 cm) laundry-type wall cap.
■ U se metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
■ T he length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
■ U se no more than three 90° elbows.
■ M ake sure there is a minimum of 24" (61 cm) of straight vent
between the elbows if more than 1 elbow is used.
■ D o not install 2 elbows together.
■ U se clamps to seal all joints in the vent system.
■ T he vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the
range hood.
■ U se caulking to seal exterior wall or roof opening around
the cap.
■ T he size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent system
enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale. Consult
your HVAC professional for specific requirements in your area.
Venting Methods
This canopy hood is factory set for venting through the roof or
wall.
A 6" (15.2 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall.
To vent through a wall, a 90° elbow is needed.
Rear Discharge
A 90° elbow may be installed immediately above the hood.
5