4. Mount the strainer. If attaching the strainer to wood, fasten with stainless steel screws. If
attaching the strainer to metal or fiberglass, first mount a wooden block and then fasten
the strainer to the wooden block.
5. Mount the pump on the strainer so that both locktabs "snaps" into place.
6. Select a point where the bilge water is to be pumped overboard as high as possible
above the water line and at the shortest distance from the pump. Install a 1½"[2200/
4000] or 1¹⁄
" [1600/2200] or 2"[4000] thru-hull fitting. Note: The 4000 pump comes
8
equipped with an integrated check valve to minimize back flow of water, however, over
time water will seep back into the hull when the pump is not running. The use of flapper
check valve will reduce maximum flow performance.
7. Fasten a 1½"[2200/4000] or 1¹⁄
from the pump outlet to the thru-hull fitting. Avoid sharp bends or loops. Support the hose
if necessary. Note: In order to prevent air locks it is important that the hose not be allowed
to dip below the pump outlet. The hose should be constantly rising.
8. Connect the brown wire to the positive (+) terminal of the battery, and the black wire to
the negative (-) termal of the battery. See wiring diagram, page 16-17.
9. Important: All electrical wiring must be clamped with the connections well above the
bilge water level. Do not remove the insulation more than necessary. All wiring
connections should be sealed with a marine sealant to avoid oxidation.
Maintenance
Regularly check the pump to be sure that the filter base and impeller are not clogged with
debris. To clean, push in the tabs and lift up the pump housing. Note! The discharge hose need
not be removed.
Accessories
ON-AUTO-OFF Panel 12V or 24V
Part No:
34-1224 (12V)
34-1225 (24V)
Electrical installation with the SPX FLOW Johnson Pump panel
Always install according to the wiring diagram on page 16-18.
Ultima Switch - Electronic Automatic Switch
Part No:
34-36303 (12V/24V)
Bilge Alert (High Water Alarm) + Ultima Switch
Part No:
34-72303-001 (12V)
34-72303-002 (24V)
Electro-Magnetic Float Switch
Part No:
34-1900B-12V (12V)
34-1900B-24V (24V)
Automatic Float Switch AS888
Part No:
34-888 (6-32V)
Waste handling & material recycling
At the products end of life, please dispose of the product according to applicable law. Where applicable,
please disassemble the product and recycle the parts material.