Télécharger Imprimer la page

Zephyr Essentials Angolo Guide D'utilisation, D'entretien Et D'installation page 11

Publicité

Les langues disponibles

Les langues disponibles

!
CAUTION: At least two installers are
required due to the weight and size of the
hood.
1. Measure from range top to hood bottom and mark line A.
(26" minimum from range top) .
2. Plum and mark center line.
3. Mark mounting height line B. (15-1/8" from line A)
4. Mark mounting spread from C/L. (8-15/16")
5. Fasten (2) M6 x 1-1/2" screws into studs on line B but
do not tighten all the way. Note: Wood blocking may
need to be added behind the drywall if no studs are
present. Wall anchors may also be used but check
local codes before using wall anchors.
6. Remove tape and (2) screws securing electronics
mounting bracket to hood. Reposition electronics
mounting bracket as shown in (FIG. B #3) and secure to
motor housing using the (2) previously removed screws.
7. Remove (2) screws securing electrical junction box to
electronics mounting plate. Remove junction box. (FIG.
B #1)
8. Remove the mesh fi lter. Hang hood onto the mounting
screws and hand tighten each screw. (FIG. A #1) Secure
third M6 x 1-1/2" screw with washer through inside of
hood into wall for extra support. (FIG. A #2)
9. Center and attach duct cover mounting bracket to wall
just below the ceiling or soffi t using (2) M6 x 1" screws.
(FIG. A #3)
10. Install duct work and seal with aluminum duct tape*.
Re-install
junction box with cable lock and install the
electrical. (FIG. B #2)
11. Power up hood to verify all functions and check for leaks
around duct tape.
12. Place telescopic duct covers onto hood and extend
inner (top) duct cover upwards and secure to duct cover
bracket using (2) M3.5 x 8 screws.
13. Place glass canopy onto unit body and secure canopy by
(4) 3/16 x 1/4 screws through fi lter opening.
14. Reinstall stainless steel mesh fi lter.
* If using hood in recirculating mode you must secure the
air diverter plate onto wall before installing duct work and
duct covers. Refer to page 10 for more details.
Cable Lock
A cable locking connector (not supplied) might
be required by local codes. Check with local
requirements and codes, purchase and install
appropriate connector if necessary.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
8
15/16
B
A
Brackets are
pre-installed
FIG. A
Cable Lock
3
9
3
Duct Cover Bracket
"
15
"
1/8
26" Min.
1
2
2
1
Motor Housing
FIG. B

Publicité

loading

Ce manuel est également adapté pour:

Zag-e30agZag-m90agZag-e30ag290Zag-m90ag290