www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
Page 5
WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION attics, crawl spaces or garages. OPERATION and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
Equivalent number Duct pieces Equivalent number Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 30”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could mounted too high will be hard to reach and will If available, also refer range manufacturer’s height i n .
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Some Ducting Options Roof Pitch w/ Flashing & Cap Side wall cap w/ gravity damper Soffit or crawl space...
ELECTRICAL WARNING how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the hood. 4” prepare hood. Refer to page 11 for horizontal ducting conversion. wood board 2. Plum and mark center line on wall. ” line A. 5.
This range hood is equipped standard with a 10” round vertical duct option. To convert from 10” round vertical to 10” round horizontal ducting please following the instructions below. VERTICAL TO HORIZONTAL DUCTING CONVERSION 1. Disconnect blower plug. attaching blower plate to top of hood body. Remove blower and blower plate.
www.zephyronline.com 1 Blower On/Off/Speed Selection 2 Lights Dim/Bright/Off 1 Blower On/Off/Speed Selection Rotate dial to change speed levels, (1) for low speed, (2) for medium speed and (3) for high speed 2 Lights Dim/Bright/Off Rotate dial to change light settings, (1) for dim light and (2) for bright light...
SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless should never need replacing, they are required to be cleaned every 30 days or more often depending on cooking habits.
www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise.
TROUBLESHOOTING PROCEDURES FOR CYPRESS Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
www.zephyronline.com MAX. USE ONLY TYPE MR16, GU10, 35 W. HALOGEN LIGHT BULBS. VOLTS MAX AMPS AK7836BS / AK7842BS CIRCUIT DIAGRAM B 34 B 34 MAX. USE ONLY TYPE MR16, GU10, 35 W. HALOGEN LIGHT BULBS. VOLTS MAX AMPS AK7848BS / AK7854BS CIRCUIT DIAGRAM B 34 B 34...
www.zephyronline.com DESCRIPTION PART # Replacement Parts Optional Accessories To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain Limited Warranty service under warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you”...
www.zephyronline.com PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.
Page 23
AK07xxAS Cypress 12” Duct Cover Duct Cover Hood Compatibility AK0736AS AK7836ASX AK0742AS AK7842ASX AK0748AS AK7848ASX 1. Line up screw holes and attach the left and right side panels to the center panel with screws provided. 2. Place assembled duct cover on top of hood. Make sure the screw holes of the center panel are facing down and line up with the holes on top of hood.
Page 25
MODELS MUA006A • MUA008A • MUA010A Page 2 AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER & PRESSURE SWITCH READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY CAUTION WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 1. Do not locate outside air inlet near hazardous materials or explosives. INJURY TO PERSONS, OBSERVE THE FOLLOWING: 2.
MODELS MUA006A • MUA008A • MUA010A Page 3 PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate MINIMUM RETURN AIR TEMPERATURE REQUIREMENTS installation approach. The chart below offers suggestions for the most HVAC equipment manufacturers may have minimum requirements for effective installation approach by considering a few important factors.
MODELS MUA006A • MUA008A • MUA010A Page 4 TYPICAL INSTALLATIONS Installations will vary according to the location in the home where the unit is installed and which model Damper is used. Use the following illustrations and notes as guidance for your own installation. Always comply with local code requirements and in any instance where a detail shown below conflicts with local code, the local code provision shall apply.
Page 28
MODELS MUA006A • MUA008A • MUA010A Page 5 INSTALL THE DAMPER INSTALLATION OF PRESSURE SWITCH AND PROBE TO CENTRAL SYSTEM SET SCREW RETURN AIR OR INTERIOR WALL REGISTER OUTSIDE AIR For the probe & pressure switch to work effectively the roof or wall cap must have a spring loaded damper.
Page 29
MODELS MUA006A • MUA008A • MUA010A Page 6 LOCATION OF PROBE AND PRESSURE SWITCH The probe must be mounted between the range hood damper The pressure switch should be mounted so it is accessible for and the wall cap, roof cap, in-line blower or external blower. any future service. The switch can mounted no more then 72”...
Page 30
MODELS MUA006A • MUA008A • MUA010A Page 7 MOUNTING POSITIONS OF PROBE & PRESSURE SWITCH DUCTWORK DUCTWORK FLOW PRESSURE PRESSURE SWITCH SWITCH PROBE TUBING (air flow arrow TUBING pointing in direction of air flow) PROBE DUCTWORK (air flow arrow HORIZONTAL pointing in direction FLOW...
MODELS MUA006A • MUA008A • MUA010A Page 8 WIRE THE SYSTEM Wire the system as shown. MAKE-UP AIR DAMPER MAKE-UP AIR DAMPER MAKE-UP AIR DAMPER WIRING DIAGRAM TRANSFORMER MULTIPLE DAMPERS TRANSFORMER PRESSURE PRESSURE SWITCH SWITCH BLACK (LINE) BLACK (LINE) WHITE (COMMON) 24V CONTACTS WHITE (COMMON) GREEN (GROUND)
MODELS MUA006A • MUA008A • MUA010A Page 9 MAINTENANCE 4. How do I know if I need make-up air for my Regular maintenance is necessary to ensure the proper operation range hood? of the Damper system. Failure to conduct such routine maintenance In some cases the local building code may tell you that make-up air is can jeopardize the ability of the Damper to introduce fresh air into the necessary.
MODÈLES MUA006A • MUA008A • MUA010A CLAPET AUTOMATIQUE D’AIR DE Page 12 COMPENSATION AVEC TRANSFORMATEUR ET MANOCONTACTEUR LIRE CES DIRECTIVES ET LES CONSERVER POUR USAGE RÉSIDENTIEL SEULEMENT ATTENTION AVERTISSEMENT OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN DE RÉDUIRE 1. Ne situez pas la prise d’air extérieur près de matières dangereuses LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE ou explosives.
MODÈLES MUA006A • MUA008A • MUA010A PLANIFICATION Page 13 DE L’INSTALLATION La planification de l’installation exige d’abord le choix du mode EXIGENCES RELATIVES À LA TEMPÉRATURE MINIMALE DE d’installation le plus approprié. Le tableau ci-dessous présente des L’ A IR DE RETOUR suggestions pour le type d’installation le plus efficace compte tenu Les fabricants d’appareils de chauffage et de climatisation ont de quelques facteurs importants.
MODÈLES MUA006A • MUA008A • MUA010A Page 14 INSTALLATIONS TYPE Les installations varieront en fonction de l’emplacement de l’appareil dans la maison et du modèle de clapet utilisé. Consultez les illustrations et notes ci-dessous pour vous guider dans l’installation. Respectez toujours les exigences des codes dans toute situation où un détail indiqué...
MODÈLES MUA006A • MUA008A • MUA010A Page 15 INSTALLATION DU CLAPET INSTALLATION DU MANOCONTACTEUR ET VERS LE RETOUR D’ A IR VIS D’ A RRÊT DU SYSTÈME CENTRAL DE LA SONDE OU UN REGISTRE AIR EXTÉRIEUR MURAL INTÉRIEUR Pour que la sonde et le manocontacteur fonctionnent correctement, le capuchon mural ou de toit doit avoir un clapet à...
MODÈLES MUA006A • MUA008A • MUA010A Page 16 EMPLACEMENT DE LA SONDE ET DU MANOCONTACTEUR La sonde doit être installée entre le clapet de la hotte et le Le manocontacteur doit être placé à un endroit accessible capuchon mural, le capuchon de toit, le ventilateur intermédiaire pour un entretien éventuel.
MODÈLES MUA006A • MUA008A • MUA010A Page 17 POSITIONS DE MONTAGE DE LA SONDE ET DU MANOCONTACTEUR CONDUIT CONDUIT DÉBIT D'AIR MANOCONTACTEUR MANOCONTACTEUR SONDE TUBE (la flèche TUBE pointe dans le sens du SONDE débit d’air) CONDUIT (la flèche pointe dans HORIZONTAL DÉBIT le sens du...
MODÈLES MUA006A • MUA008A • MUA010A Page 18 CÂBLAGE DU SYSTÈME Effectuez le câblage tel qu’illustré. CLAPET D'AIR DE COMPENSATION CLAPET D'AIR DE COMPENSATION CLAPET D'AIR DE COMPENSATION TRANSFORMATEUR MANOCONTACTEUR TRANSFORMATEUR MANOCONTACTEUR NOIR (LIGNE) DIAGRAMME DE CÂBLAGE BLANC (NEUTRE) CLAPETS MULTIPLES VERT (TERRE) NOIR (LIGNE) DIAGRAMME DE CÂBLAGE...
MODÈLES MUA006A • MUA008A • MUA010A Page 19 ENTRETIEN un débit de 300 pieds cubes par minute (pi /m) ou plus exigent un Un entretien régulier est nécessaire pour garantir le bon dispositif mécanique d’apport d’air de compensation. Dans d’autres cas, fonctionnement du système de clapet.