Télécharger Imprimer la page

Calorex AW629 Mode D'emploi page 20

Publicité

Les langues disponibles
  • FR

Les langues disponibles

DATA SHEET
MODEL
HEAT TO POOL WATER
AMBIENT 10°C, WATER 24°C
AMBIENT 20°C, WATER 24°C
ELECTRICITY
ELECTRICAL SUPPLY 1 PHASE
TOTAL POWER CONSUMED
AMBIENT 10°C, WATER 24°C
AMBIENT 20°C, WATER 24°C
MIN SUPPLY CAPACITY (Max F.L.A.) 1 ph N:-
MAX SUPPLY FUSE 1 ph N:-
WATER FLOWS ETC
POOL WATER FLOW RATE:-
POOL WATER PRESSURE DROP (@ Rated Flow):-
MAX WORKING PRESSURE POOL WATER:-
POOL WATER CONNECTIONS:-
CONDENSATE DRAIN CONNECTIONS:-
COMPRESSOR
NOMINAL POWER CONSUMED
L.R.A. 1 ph N:-
R.L.A. 1 ph N:-
SOFT START AMPS 1 ph N:-
MAIN FAN
AIR FLOW (Anemometer @ air on grille. Wet evaporator):-
MAX EXTERNAL STATIC PRESSURE:-
F.L.A. 1 ph N:-
GENERAL DATA
HERMETIC SYSTEM
GAS CHARGE
R407c
PHYSICAL DIMENSIONS
WIDTH (Unpacked):-
DEPTH (Unpacked):-
HEIGHT (Unpacked):-
WEIGHT (Unpacked):-
For Accurate Application Sizing Consult CALOREX Heat Pumps Ltd.
NOTES:-
1) Weight and dimensions nett
2) Performance design Iimitations
Ambient = 7°C min, 40°C max
Water = 10°C min, 40°C max
3) Pool water to have correct balance, pH 7.4 ± 0.4 Free Chlorine 1.0 - 3.0 ppm
4) Allow 500mm clearance to service panels
5) Calorex reserve the right to change or modify models without prior notice.
6) R407c Global warming potential (GWP) 1700.
1mm WG = 9.8 Pa
1m hd = 1.4 psi
1L/min = 0.22 gall/min
HEAT PUMPS FOR OUTDOOR POOLS
SUMMER SEASON (AL, BL)
Units
kWhr
kWhr
kWhr
kWhr
m hd
inches
inches
kWhr
m³/hr
mm Wg
Page 20
AW629
7.2
9.2
230V/~1N/ 50Hz
1.8
2.0
A
14.3
A
20.0
l/mn
115
1.1
bar
3.5
1 1/2" BSPM
3/4"BSPM STUD 3/4"BSPM STUD
1.8
A
66
A
11.4
A
29
1800
0
A
0.7
kg
1.6
mm
1049
mm
577
mm
787
kg
??
AW829
9.9
12.5
2.3
2.5
17.6
25.0
115
1.1
3.5
1 1/2" BSPM
2.14
63
14
28
2700
0
0.7
2.05
1227
577
787
??

Publicité

loading

Ce manuel est également adapté pour:

Aw829