- Parameters
Each system requires a different parameterisation. Follow the access procedure given below.
"System Type Menu"
Change parameter P.01 of the "System Type Menu" to 4.
Change parameter P.09 of the "System Type Menu" to 1.
- Optional features
In addition to the electrical connections of the previous figure (necessary for this system configuration) there are options
that do not require settings.
J2
J1
156
J3
fig. 39
cod. 3541R964 - Rev. 01 - 02/2022
Legend (fig. 39)
139 Remote control: it can be installed instead of 72
to manage the request of the 1st zone (direct)
300 Burner on indication (voltage-free contact
output): the example shows the connection of a
230 Vac hour meter
301 Fault indication (voltage-free contact output): the
example shows the connection of a 230Vac
lamp
302 Remote reset input (230Vac): the example
shows the connection of a double-pole switch at
230Vac, allowing the resetting of a block type
fault
357 Fault indication (230Vac): the example shows
the connection of a 230Vac lamp