Function and features
The DC0103 monitors rotational speeds (mainly with regard to under-
speed).
It takes pulses from external pulse pick-ups and switches the output relay
depending on the set switch point max (D
The output relay
- is energised when the maximum
rotational speed is reached
- is de-energised when the speed
is below the min. rotational
speed.
• Setting range: 30 ... 25 000 pulses /min.
• Intelligent switch point setting while machine is in operation ("teach-in").
Controls and indicators
1 2 3
S1, S2, S3: programming buttons
H6: red LED flashes when D
H7: red LED flashes when D
H8: green LED , supply voltage
H9: green LED is lit when the relay is energised
H10: yellow LED, indication of the input pulses
1 2 3
X1
X2
max
H8
H10
H9
1 2 3
X3
is programmed
min
is programmed
max
) and switch point min (D
Dmin
Dmin
H7
H6
1 2 3
X4
).
min
Dmax
Dmax
S1
S2
S3

Publicité