2.
Prime period is defaulted to 5 minutes and high speed. We recommend if your pump is installed at or
below water level, you change the PRIM to 2 minutes. Press ENTER and then Up or Down arrows to
change the prime speed. Press ENTER to accept. Priming period will now be displayed.
3.
Use the Up or Down arrow to change the Priming period. Press ENTER to accept.
4.
Press MENU to go to TMR "timer settings" and press ENTER to change.
5.
Timer 1 is factory set to start at 8 am. Use up or down arrows to change. Press High, Medium, or Low to
select the speed of the pump during Timer 1. On the LCD Screen Low is represented by "speed 1", medium
by "speed 2", and High by "speed 3".
6.
Press ENTER to move to the stop or end time of Timer 1. Use the up and down arrows to change the end
of Timer 1.
7.
Timer 2 will now appear on the LCD Screen. Repeat instructions 4. to 6. Above.
8.
Timer 3 will now appear but is factory preset to OFF. Moving any timer to midnight will turn that Timer
period off. Use the up and down arrows to activate the time and repeat process 4 and 5 above.
9.
Timer 4 is also factory preset to "off" but can be activated by using the up and down arrows.
10. Remember to select the speed you wish to operate during each timer period by pressing the High,
Medium or Low buttons while still in the Timer Start program.
Using the in built pump timers with a non compliant chlorinator or dosing unit.
1.
We do not recommend the use of the pump timers when a non compliant chlorinator or chemical doser is
supplied water flow by the Viron P320 or P600 eVo pump.
2.
In this case, the pump operating hours should be controlled by the chlorinator time clock and the pump
plugged into the chlorinator. This is a safety measure provided for by most chlorinator manufacturers.
3.
However, it is important to deactivate the inbuilt pump timers.
4.
Toggle MENU until "CONF" is displayed on the LCD screen.
5.
Press and HOLD ENTER for 3 seconds.
6.
Toggle MENU until "TMR" appears.
7.
Press UP or Down buttons to turn "TMR" off.
8.
Press ENTER to accept.
9.
Press
"auto" to return to main menu.
10. When cycling through the MENU button TMR will no longer appear.
11. You will no longer be able to automatically have the speed of the pump changed during different times
opf the day.
12. However, if you wish for a period where the pump operates at a high speed, for example to circulate the
water vigorously for a part of the daily filtration, you can use the PRIMING setting to do so.
Using the PRIMING program to circulate the water at a higher flow rate for part of the daily filtration cycle.
1.
Toggle MENU to go to PRIM setting.
2.
Prime period is defaulted to 5 minutes and high speed. Use the up and down arrows to change the
Priming period up to 120 minutes. Use the High, medium, or low buttons to select the speed you wish the
pump to operate for during the Priming period. In this case, we recommend the High Speed button be
selected.
3.
Press "auto" to exit the programming.