Télécharger Imprimer la page

Mitsubishi Electric PAR-21MAA Livret D'instructions page 13

Masquer les pouces Voir aussi pour PAR-21MAA:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
2 Using the Simple Timer
I You can set the simple timer in any of three ways.
• Start time only:
The air conditioner starts when the set time has elapsed.
• Stop time only:
The air conditioner stops when the set time has elapsed.
• Start & stop times: The air conditioner starts and stops at the respective elapsed
times.
I The simple timer (start and stop) can be set only once within a 72-hour period.
The time setting is made in hour increments.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same time.
*2. The simple timer will not operate when any of the following conditions is in effect.
The timer is off; the system is in malfunction state; a test run is in progress; the
remote controller is undergoing self-check or remote controller check; the user is in
the process of selecting a function; the user is in the process of setting the timer; the
system is under central control. (Under these conditions, On/Off operation is
prohibited.)
TEMP.
MENU
ON/OFF
BACK
MONITOR/SET
DAY
PAR-21MAA
CLOCK
2
A
9
Hr
ON
AFTER
SIMPLE
1
ON/OFF
B
FILTER
4
CHECK
TEST
0
OPERATION
CLEAR
<How to Set the Simple Timer>
2
1. Be sure that you are at a standard control screen, and that the simple timer indicator
is visible in the display (at 1).
When something other than the Simple Timer is displayed, set it to SIMPLE TIMER
using the function selection of remote controller (see 6.[4]–3 (3)) timer function setting.
2. Press the Timer Menu button B, so that the "Set Up" appears on the screen (at 2).
(Note that each press of the button toggles the display between "Set Up" and
"Monitor".)
3. Press the ON/OFF button 1 to display the current ON or OFF simple timer setting.
Press the button once to display the time remaining to ON, and then again to display
the time remaining to OFF. (The ON/OFF indication appears at 3).
• "ON" timer: The air conditioner will start operation when the specified number of
hours has elapsed.
• "OFF" timer:The air conditioner will stop operation when the specified number of
hours has elapsed.
4. With "ON" or "OFF" showing at 3: Press the appropriate Set Time button A as
necessary to set the hours to ON (if "ON" is displayed) or the hours to OFF (if "OFF"
is displayed) at 4.
• Available Range: 1 to 72 hours
5. To set both the ON and OFF times, repeat Steps 3 and 4.
* Note that ON and OFF times cannot be set to the same value.
6. To clear the current ON or OFF setting: Display the ON or OFF setting (see step 3)
and then press the Check (Clear) button 0 so that the time setting clears to "—" at
4. (If you want to use only an ON setting or only an OFF setting, be sure that the
setting you do not wish to use is shown as "—".)
7. After completing steps 3 to 6 above, press the Filter
Note:
Your new settings will be cancelled if you press the Mode (Return) button 2 before
pressing the Filter
button 4.
8. Press the Mode (Return) button 2 to return to the standard control screen.
9. Press the Timer On/Off button 9 to start the timer countdown. When the timer is
running, the timer value is visible on the display. Be sure that the timer value is
visible and appropriate.
– 13 –
4
Timer Setting
3
Action (On or Off)
Hr
ON
AFTER
* "— —" is displayed if there is no
setting.
1
SIMPLE
button 4 to lock in the value.

Publicité