Safety Information
This device may only be used for the purposes described in these instructions. The
manufacturer cannot be held liable for damage caused by incorrect application.
The non contact infrared body thermometer is designed to minimize the possibility of
hazards from errors in the software program by following sound and light engineering
design processes, Risk Analysis and Software Validation.
Warning
• The non contact infrared body thermometer is a medical device, and can be used
repeatedly, which using life is 5 years.
• The Non Contact Infrared Body Thermometer is to be operated by consumers in the
home setting and primary care setting as screening tool. This manual, accessories,
Directions for Use, all precautionary information, and specifications should be read
before use.
• This product is designed to measure human body temperature on the forehead. Do
not use it for any other purpose.
• This product is intended in the home setting and primary care setting as screening
tool.
• Do not use the thermometer if it malfunctions or has been damaged in any matter.
• When the ambient temperature of the thermometer changes too much, such as
moving the Thermometer from one place of lower temperature to another place
of higher temperature, Allow the thermometer to remain in a room for 30 minutes
where the temperature is between15℃to 40℃ (59℉- 104℉).
• Remove primary batteries if equipment is not likely to be used for long time.
• This product is not waterproof, do not be immersed in water or other liquid; If clean-
ing and disinfection, please follow the "Care and Storage" section requirements.
• Do not touch the sensor of infrared detection with your fingers.
• If a cold compress on the forehead fever patients, or take other measures to cool
down the temperature data will low, should be avoided in this case to measure body
temperature.
• If measure human forehead temperature , please select "body" mode; for measure
other objects, liquids, food and other temperature please select "surface" mode.
• This product must be operated in a stable environment, if the ambient environment
was mutations, please should be note whether there is fog on the sensor, if any,
before using accordance with the "Care and Storage" section to removing the fog.
• Do not near strong electrostatic field or strong magnetic fields, thus avoiding the
impact on the accuracy of the measurement data.
• Do not mix the old and new batteries to avoid damage to the product.
• It may affect the accuracy of measurements when the forehead is covered by hair,