6.5 Adjusting the mechanical end stops (standard on PWR50H/HR)
Bring the gate wing to its fully open or closed position. Loosen the mechanical end stops with a
4mm Allen wrench, just enough so that they can slide along the drive screw, then move them up
against the split nut and fix them in place.
4 mm
4 mm
6.6 Adjusting magnetic limit switch (standard on PWR50HV)
Bring the gate wing to its fully open or closed position. Loosen the limit switches with a Phillips
screwdriver, just enough so that they can slide along the guide, then bring them above the split
nut [16] until the magnetic sensor is activated. Fix them in place.
33