● Assemble the process prior to the electrical installation.
● Make sure prior to mounting that the device is appropriate with regard to the process connection, media compatibility,
temperature resistance and measuring range.
● The gaskets used must be suitable for the process connection and resistant to the measured media.
Note
SITRANS TS500 barstock version
For SITRANS TS500 barstock version without flange (type 4), the customer has to complete the mounting of the device
extension to the protective tube, see Device extension and protective tube torque requirements table below
CAUTION
Gasket between extension and protective tube
Gasket between device extension and protective tube can only be used once
● Use required torque values between device extension and protective tube, see Device extension and protective tube
torque requirements table below.
● Use required torque values between the device head and extension if customer adjustments are necessary (M24
connections only), see Device device head and extension torque requirements table below.
Table 4-1
Device extension and protective tube torque requirements
Connection type
M14 thread
M18 thread
G½ thread
Table 4-2
Device device head and extension torque requirements
Head type
Metal head
Plastic head (BP0)
Plastic head (BM0)
Rule of thumb for installation
Prevent faults caused by heat dissipation by observing the following rules:
● Select the largest possible immersion depth. Estimate the immersion depth using the formulas specified below.
● Select a measuring location with a high flow rate.
● Ensure that there is sufficient thermal insulation of the external components of the thermometer.
● Ensure that external parts have as small surfaces as possible.
● Select the optimum mounting position for the process in question.
Estimation of immersion depth
Medium
Immersion depth (calculation)
Water
Immersion depth ≥ TSL + (5 x ∅
Air
Immersion depth ≥ TSL + (10 bis 15 x ∅
TSL = Temperature Sensitive Length
1)
SITRANS TSinsert/TS100/TS200/TS300/TS500
A5E03920348-04, 09/2013
Torque value
25 Nm
40 Nm
50 Nm
Torque value
28 Nm
15 Nm
5 Nm
1)
)
protective tube
)
protective tube
13