Loosen and remove screw
Turn fully CCW
RE-CALIBRATION PROCEDURE
1. To re-calibrate the valve, it is necessary to
gain access to the spindle (located behind
the temperature extension near the top of
the valve).
2. Turn the temperature extension counter-
clockwise until it stops.
3. Loosen and remove the screw in the center
of the temperature extension by turning it
counterclockwise.
4. Carefully remove the temperature extension
without turning it or the spindle behind it.
You have now accessed the spindle.
5. To increase the temperature, rotate the
spindle counter-clockwise one or two
spline(s) past the mark on the retaining nut.
To decrease the temperature, rotate the
spindle clockwise one or two spline(s) past
the mark on the retaining nut.
6. Replace
the
temperature
positioned fully counter-clockwise with the
tab as close as possible to the clockwise
side of the pin in the retaining nut. This
should be done without rotating the spindle.
Do not install the screw at this time.
7. Turn the flow handle counter-clockwise to
start the flow of water.
Spindle with
temperature
extension in place
8. After the water temperature has stabilized,
check the temperature. This will be the new
maximum temperature. If the temperature is
not suitable, remove the temperature
extension as described above and repeat
this procedure to further adjust the water
temperature.
extension,
9. When
the
acceptable, re-install the screw in the
temperature extension and tighten.
10. Refer
to
instructions on how to re-attach the
temperature knob.
Temperature
extension tab
Temperature extension
Spindle
Retaining nut pin
Increase temperature
Decrease temperature
Spindle w/ temperature
extension removed
Retaining nut pin
maximum
temperature
"Attach
Temperature
Knob"
is
6