Aligning The Sct 410 By Setting Aid; Removing The Precision Measuring Bar From The Sct; Adjusting The Height Of The Calibration Board - Bosch SCT 410 Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
4.3.1

Aligning the SCT 410 by setting aid

i
The setting aid is available as an optional accessory.
1. Place setting aid (Fig. 9, item 1) on star knob screw.
2. Use the setting aid (Fig. 9, item 1) to align the
SCT 410 by way of the spirit levels on the precision
measuring bar (Fig. 8, item 1 and item 2).
Fig. 9:
Aligning the SCT 410 by setting aid
1 Setting aid
4.4
Removing the precision measuring
bar from the SCT 410
1. Secure the precision measuring bar by hand.
2. Remove the star knob screw.
3. Remove clamp (Fig. 4, item 1).
4. Remove the precision measuring bar from the angle
mounting bracket.
Robert Bosch GmbH
1
Operation | SCT 410 | 15
4.5
Adjusting the height of the calibrati-
on board
1. Find the required height of the calibration board in
the "Multi-Target-Shop short instructions".
2. Check if there is a difference in height between the
resting surface of the vehicle and the resting surface
of the SCT 410 (for example due to a lift).
3. If there is a difference in height between the resting
surfaces, compensate for it by adjusting the height
given in the short instructions.
4. Attach the calibration board to the precision measu-
ring bar.
5. Operate the locking handle and use a tape measure
to set the calibration board to the required height.
6. Measure the required height with a tape measure at
the center of the calibration board (Fig. 10, item 3).
1
Fig. 10:
Setting calibration board height
1 Locking handle
2 Calibration board
3 Center of calibration board
x
Required height from the ground to the center of the calibration
board
en
2
3
x
|
1 690 386 066
2017-08-11

Publicité

Table des Matières
loading