Télécharger Imprimer la page

Delabie TEMPOSTOP Mode D'emploi page 8

Masquer les pouces Voir aussi pour TEMPOSTOP:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
OPERATION
Valve opens by pressing on the push-button or pushing the lever.
AB Model: valve opens by pressing then releasing the push-button.
Mixer: temperature selection by the side lever.
Automatic shut-off after ~7 seconds for washbasins, ~3 seconds
or 7 seconds for urinals (depending on the model), and ~30 seconds
for showers (+5/-10 at 3 bar according to the European Standard
EN-NF 816). (Other shut-off delays: TEMPOSTOP swan neck
~3 seconds, TEMPOSTOP chain-pull shower and TEMPOSTOP
shower 1/2" ~15 seconds).
INSTALLATION
Tap: supply with cold water (insert the blue or grey marker)
or mixed water (insert the red marker).
Mixer: supply with cold water and hot water at 50°C (maximum
recommended 70°C), and balance hot and cold water pressure
(∆P < 1 bar). Maximum pressure: 10 bar. Recommended dynamic
pressure: 1 - 5 bar. Take care not to pinch the flexibles (Fig. A).
Respect the direction of the water flow, see arrow marked
on the valve body.
Deck-mounted washbasin model:
Drill hole diameter: Ø 21mm for taps or Ø 34mm for mixers.
Mount the mixer/tap body onto the washbasin and tighten the nuts:
- Model with back-nut: tighten the 3 stainless steel screws
on the back-nut (Fig. B).
- Mixer: tighten the nuts (Fig. C) onto the fixing flange.
Install the filters (Fig. D) supplied as shown in the diagram.
They will protect the non-return valves.
Ensure a suitable waterproof seal between the mixer/tap
and the work plan appropriate to the type of installation.
Connect the water supply and activate the valve several times
to stabilise the timing.
Wall-mounted models:
Drill a hole Ø 21mm.
Connect the water supply and activate the valve several times
to stabilise the timing.
Exposed wall-mounted models (except ref. 749001):
Fix the mixer/tap to the wall with the screw(s) supplied
(the rawl plugs should be suitable for the type of wall).
Connect the water supply and activate the valve several times
to stabilise the timing.
EN

Publicité

loading

Ce manuel est également adapté pour:

Tempomix 2Tempogenou