Recessed model
•
Allow a recessing area 90 x 90 mm. The depth can be adjusted
from 55 - 75mm.
•
Connect the valve to the water supply.
•
Mount the stainless steel wall plate against the wall and position
the silicone seal behind the wall plate to provide a waterproof seal
between the wall plate and the wall. Leave a drainage point to allow
any residual water to drain away.
•
Activate the valve several times to stabilise the timing.
THE INSTALLER MUST ENSURE:
•
THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF
TO PREVENT ANY INGRESS OF WATER;
•
ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING
(E.G. CONDENSATION, RUN OFF, LEAKS, ETC.) HAS A DRAINAGE
POINT TO PREVENT ANY STAGNATION;
•
THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL
WALL PLATE AND THE WALL OR THE WALL PLATE AND
THE MIXER/TAP/VALVE AT LEAST ONCE A YEAR, AND MAKE
GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL
SUPPORT, UK: 01491 821821.
ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
REMEMBER
Our valves must be installed by professional installers
•
in accordance with current regulations and recommendations
in your country, and the specifications of the fluid engineer.
Sizing the pipes correctly will avoid problems of flow rate,
•
pressure loss and water hammer (see calculation table in our brochure
and online at www.delabie.com).
Protect the installation with filters, water hammer absorbers
•
and pressure reducers to reduce the frequency of maintenance
(recommended pressure from 1 to 5 bar maximum).
Install stopcocks close to the valve to facilitate maintenance.
•
•
The pipework, filters, non-return valves, stopcocks, bib taps,
cartridge and all sanitary fittings should be checked at least once
a year, and more frequently if necessary.
EN