Electrical Requirements - Luminance Brands Kathy Ireland 4th AVENUE LED CF766LBQ00 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. Unpacking Instructions
This Manual Is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips Head Screwdriver
One 1/4" Blade Screwdriver
Materials
Wiring outlet box and box connectors must be of type
required by the local code . The minimum wire would be
a 3-conductor (2-wire with ground) of following size:
Installed Wire Length
Up to 50 ft .
50-100 ft .
Your New Ceiling Fan will require a Grounded Electrical
Supply Line of 120 volts AC, 60 Hz, 15 amp circuit .
The Outlet Box must be securely anchored and capable
of withstanding a load of at least 50 Pounds .
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable
for Fan Support of 22.7 kg. (50 lbs.) or less", and
use screws supplied with outlet box. Most outlet
boxes commonly used for support of light fixtures
are not acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
If your Fan is to replace an Existing Ceiling Light
Fixture, turn Electricity Off at the Main Fuse Box or
Circuit Breaker Panel at this time and remove the
Existing Light Fixture .
One Stepladder
One Wire Stripper
Wire Size A .W .G .
14
12

2. Electrical Requirements

(Continued)
!
Before assembling your ceiling fan, refer to section
on proper method of wiring your fan (page 12).
If you feel you do not have enough wiring knowledge
or experience, have your fan installed by a licensed
electrician.
Remote Control
SR401 Remote Control (sold separately) may be used
with this 60" 4th AVENUE LED Ceiling Fan . Controls
are recommended for indoor use only .
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box or circuit breaker panel before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
!
To avoid fire or shock, follow all wiring instructions
carefully.
A n y e l e c t r i c a l w o r k n o t d e s c r i b e d i n t h e s e
instructions should be done or approved by a licensed
electrician.
Please call Customer Service at 1-800-777-4440
if you have any questions about installation and
operation of this Ceiling Fan .
4
WARNING
(sold separately)
WARNING
WARNING
ETL Model No.: CF766L

Publicité

Table des Matières
loading

Table des Matières