5 - Maintenance
ATTENZIONE: Quick
that shuts down power supply in case of an excessive water temperature.
If it happens, follow the instructions below:
• shut down power supply.
• Remove the protection cover (14) in order to reach the thermostat.
• Adjust the thermostat knob with a screwdriver (fig. 4 pag.7) adjust the thermostat to its max temperature.
• Push the reset button on the double thermostat (fig.4 pag.7).
• Re-adjust the thermostat knob with a screwdriver (fig.4 pag.7) and turn it until the required temperature.
• Replace on the protection cover (14).
• Switch on power supply.
WARNING: if the high temperature safety system switches on repeatedly, call Quick
We recommend checking the magnesium anode (A) every 12 months. Replace the anode if its size has been
reduced significantly. This simple and preventive maintenance will ensure a long life of the equipment.
During wintertime, when the water heater is not in use it should be drained using the lever of the valve. This is
to avoid serious damage caused by freezing.
F
Periodically check the joints of the water pipe installation; check the tightness of the securing screws
and replace them in case they are worn or corroded.
Also periodically check the electrical system working order.
6 - Disposal of the product
As in installation, also at the end of product lifetime, the disassembly and scrapping operations must be
performed by qualified personnel.
This product is made up of different types of material, some of which can be recycled while others must be
disposed of. Seek information on the recycling and disposal systems envisaged by the local regulations in your
area for this product category.
Some parts of the product may contain polluting or hazardous substances which, if disposed of into the
environment, constitute serious environmental and health risks.
As indicated by the symbol, the product may not be disposed of as domestic waste. Sort the materi-
als for disposal, according to the methods envisaged by current legislation in your area, or return the
product to the retailer when purchasing an equivalent product.
Local legislation may include the application of serious fines in the event of improper disposal of this product.
nautic water heaters are provided with a double thermostat with manual reset
®
INSTALLATION AND USER MANUAL QUICK BX BOILER - REV007A
BX
EN
service center.
®
BX
15