V4.1
Tpr - Gas
pre-flow time
Unit
S
Setting range
0.1-3
Factory setting
0.3
I2 - Second current/Spot time/I-Spot frequency
Mode
Item
Repeat
Second Current
Spot
Spot Time
I-Spot
I-Spot Frequency
Iw - Pulse Peak Current
Unit
A
Setting range
10-200 (TIG-DC)
10-200 (TIG-AC-HF)
30-200 (TIG-AC-LIFT)
Factory setting
50
Only selectable when 'pulse key' has been pressed.
1
The values for Ib and lw cannot differ greatly.
2
Fp - Pulse frequency
Unit
Hz
Setting range
0.5-200
Factory setting
0.5
Only selectable when 'pulse key' has been pressed.
1
Tpo - Gas post-flow time
Unit
S
Setting range
0.3-10
Factory setting
3
Balance adjustment is mainly used to set the adjustment of eliminating metal-oxide (such as Aluminum, Magnesium
3
and its alloy) while AC output.
Visit www.princessauto.com for more information
SMART TIG AC/DC-200P Inverter Welding Machine
Is - Starting current
(only with 4T)
A
10-200 (DC)
10-200(AC-HF)
30-200 (AC-LIFT)
10
Range
10-200 (DC HF and DC LIFT)
10-200 (AC-HF)
30-200 (AC-LIFT)
0.1-30
0.5-6
Ib - Base current
A
10-200 (TIG-DC)
10-200 (TIG-AC-HF)
30-200 (TIG-AC-LIFT)
10
Tdown - Downslope time
1
S
0-10
0.3
AC frequency (only with TIG-AC)
Hz
20-250 (T1 < 50A)
20-200 (50A ≤ I1 < 100A)
20-150 (IOOA ≤ I1 < 150A)
20-100 (150A ≤ I1 < 200A)
---
Tup - Upslope
I1 - Welding current
time
S
Unit
0-10
Current
Ranges
0.3
Dcy - Ratio of pulse duration to
1 2
base current duration
%
5-100
5
Ic - Crater arc current (only with 4T)
S
10-200 (DC)
10-200(AC-HF)
30-200(AC-LIFT)
30
A
10-200 (TIG-DC),
10-200 (TIG-AC-HF)
30-200 (TIG-AC-LlFT)
10-170 (MMA-DC)
10-170 (MMA-AC)
Factory
30
1
0.5
1
Balance (only with TIG-AC)
%
15-50
15
8560237
Unit
A
S
Hz
3
11