W orking logic
"Step-by-Step" logic (Dip 1 = OFF Dip 2 = ON)
A Start control puts into motion, a following control stops the motion, a further Start control reverses the motion (direction reverse).
"Automatic closing" (Dip 1 = ON Dip 2 = ON)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied during the pause interrupts work
cycle and the gate doesn't close automatically. Photocell intervention during pause time reloads it, extending the period before automatic closing.
"Condominium" logic (Dip 1 = not influent Dip 2 = OFF Dip 3 = not influent)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied while opening is not influent.
A Start control supplied while closing provokes the stop and gear reverse after approx. 1,5 sec.. A Start control or Photocell intervention during
pause time reloads it, extending the period before automatic closing.
WARNING: after each modification of the working logic, switch the control unit off and on again to make the change active.
"Immediate closing" (DP3=ON
DP2=ON)
In opening phase and during pause time, after having passed the Photocell, it determines the stop and, after 1,5 sec., gate closing.
Programming
Learning of remote controls
To enter a Start code, press the P1 key once. To enter a Pedestrian start code, press the P1 key twice. Each time the P1 key is pressed, the DL1 led
emits a short flash. After 3 seconds from the last pressure of P1, the DL1 led turns on with a steady light. Then press the key to be memorized on the
remote control. The DL1 led will switch off, indicating that the code has been memorized. If the code is not recognized, the DL1 led stays on for
10 sec., after which it will automatically switch off .
Erasing of all memorized codes
To delete all the stored codes, keep the P1 key pressed for approx. 10 sec. until the DL1 led turns off.
Setting of pause time
To set the pause time, press the P2 key once. DL1 led emits a short flash and, after 3 sec., turns on with a steady light. Let pass the time
corresponding to the desired time and press again the key P2.
Programming of work time
Make sure the gate is completely opened. Press button P3 for approx. 3 sec. until DL1 led turns on with steady light and the gate start to close.
Wait for the gate to reach the closing limit switch. The gate stops and the Led DL1 switches off, signalling the end of the programming.
The program automatically computes the point of slowing down start (1/8 of stroke). To modify it, while programming press the key P3 in the
wished point during closing step.
Technical data
Card dimensions and weight: 170 x 70 x 45 mm – 0,14 Kg
Card power supply (Vin): 20 Vac
Stand-by power consumption: approx. 1 W
Operating temperature range: 0 to + 60 °C
Brushless motor power supply: 24 Vdc
Blinker power supply (LED): 12 V 3 W max.
Accessories power supply: 12 Vdc 3 W max.
Pause time regulation: 1 to 300 sec. %
DECLARATION OF CONFORMITY
Device description: Electronic board controlling a 24 Vdc Brushless motor destined to sliding gate automation.
Model:
CTR640
Applied rules:
EN 61000-6-3, EN 61000-6-1, EN 301489-1, EN 301489-3, EN 300220-2, EN 300220-1, EN 60950-1
Test laboratory:
NEMKO SPA
The manufacturer declares that above mentioned products comply with rules required by European directives 2004/108/EC and 2006/95/EC.
Date: 15-07-2020
CONNECTIONS
DS1
1 2 3
ON
DS1
OFF
Receiver