Prior to installation, decide on the following:
1. Where the smoke outlet should be.
2. Position of external air connection if being used (see «4.5
External Air»).
3. Ash collection system if being used.
Refer to manuals for parts installation instructions.
Fig. 3
F
E
C
D
A
B
Once the burn chamber has been unpacked, take the box
containing the smoke bell, log retainer (Fig. 3 C), gasket and bag
of screws out of the burn chamber. Then remove the air duct (Fig.
3 D), baffle (Fig. 3 B), exhaust deflector (Fig. 3 A), side burn plates (Fig.
3 E) and then the rear burn plate (Fig. 3F).
NB: The burn plates are made of a porous material (yellow
vermiculite) and may be damaged if they are handled roughly.