ATOM
ERROR 193
ERROR 194
ERROR 197
OVER CURRENT CHARGE (# OCC)
ERROR 198
OVER CURRENT DISCHARGE (# OCD)
ERROR 199
ERROR 204
TEMPERATURE CHARGING (# TCA)
ERROR 205
TEMPERATURE DIISCHARGING (# TDA)
CELL OVER VOLTAGE (# COV)
CELL UNDER VOLTAGE (# CUV)
SHORT CIRCUIT (# SCD)
USER MANUAL
1) DISCHARGE FULLY THE BATTERY.
2) RECHARGE FULLY THE BATTERY WITH ORIGINAL
CHARGER.
3) AFTER FULLY CHARGE, KEEP CHARGER PLUGGED-IN
FOR 2 HOURS TO BALANCE THE CELLS.
4) RESTART THE SYSTEM.
5) IF ERROR DOES NOT DISSAPPEAR, CONTACT A BH DEALER.
1) DISCHARGE FULLY THE BATTERY.
2) RECHARGE FULLY THE BATTERY WITH ORIGINAL
CHARGER.
3) AFTER FULLY CHARGE, KEEP CHARGER PLUGGED-IN
FOR 2 HOURS TO BALANCE THE CELLS.
4) RESTART THE SYSTEM.
5) IF ERROR DOES NOT DISSAPPEAR, CONTACT A BH DEALER.
1) CHECK STATUS OF THE ORIGINAL CHARGER.
2) RESTART THE SYSTEM.
3) IF ERROR DOES NOT DISSAPPEAR, CONTACT A BH DEALER.
1) RESTART THE SYSTEM.
2) IF ERROR DOES NOT DISSAPPEAR, CONTACT A BH DEALER.
1) CHECK CHARGER CABLE STATUS.
2) RESTART THE SYSTEM.
3) IF ERROR DOES NOT DISSAPPEAR, CONTACT A BH DEALER.
1) STOP CHARGING FOR 30 MINUTES.
2) RESTART THE SYSTEM.
3) IF ERROR DOES NOT DISSAPPEAR, CONTACT A BH DEALER.
1) RESTART THE SYSTEM.
2) IF ERROR DOES NOT DISSAPPEAR, CONTACT A BH DEALER.
EN
57