Installation
Priming plug
Priming tee
Suction
pipe
Standing water
20' (6 m) max.
level (pump off)
Drawdown water
level (pump on)
10-20' (3-6 m)
At least 5 feet (1.5 m)
Foot
Valve
828 0993
Figure 5 – Cased/Dug Well Installation
Check valve
Steel drive pipe
Drive coupling
Driven point
745 0993
Figure 6 – Driven Point Installation
4 0
6 0
2 0
8 0
1 0 0
Figure 7 – Multiple Discharge
1909 0997
For parts or assistance, call Simer Customer Service at 1-800-468-7867
Dug Well Installation
Same as cased well installation.
Driven Point Installation
NOTICE: More than one driven point may be needed to give adequate
water flow to pump.
1. Connect the suction pipe to the drive point as illustrated in Figure 6.
Keep horizontal pipe run as short as possible. Use Teflon tape on
male pipe threads. Multiple well points may be necessary to provide
sufficient water to pump.
2. Install a check valve in horizontal pipe. Flow arrow on check valve
must point toward pump.
Horizontal Piping From Well To Pump
1. Never install a suction pipe that is smaller than the suction port of
the pump.
2. To aid priming on well point installations, install a line check valve as
shown in Figure 6. Be sure check valve flow arrow points toward pump.
Discharge Pipe Sizes
1. If increasing discharge pipe size, install reducer in pump discharge port.
Do not increase pipe size by stages.
2. When the pump is set away from the points of water use, the discharge
pipe size should be increased to reduce pressure losses caused
by friction.
• Up to 100' run: Same size as pump discharge port.
• 100' to 300' run: Increase one pipe size.
• 300' to 600' run: Increase two pipe sizes.
Lawn Sprinkling Application
This pump is designed for lawn sprinkling. It is designed to deliver plenty
of water at full sprinkler pressure. It can pump from a pond, cistern or
well points.
Pump discharge can be divided to supply two (2) or more sprinkler systems.
A suggested multiple discharge to service is shown in Figure 7.
Do not use in a pressure tank or booster pump application. Please call
Simer customer service for additional information, if desired.
Maximum running pressure is 40 PSI.
5