6 |
Technical data
General technical data:
Characteristic
System voltage
- no recognition
- recognition 12 V
- recognition 24 V
Operating voltage
Overcharge protection
Temp. compensation
Control frequency
Max. terminal voltage
Total discharge protection
- Switch-on/switch-off delay
Nightlight function
- switch on
- switch off
- Switch-on/switch-off delay
Display
Terminals
Fuses on B1, B2
Power required by the unit (illuminated) 7,0 (18,0) mA
Voltage loss
Ambient conditions
Storage conditions
Battery selector switch
Type of protection
Weight
29
Value/Unit
12V / 24V automatic
< 6V
6V – 17.0V
> 17.0V
8,5V ... 35V
max. 20A @ 25°C
-20mV/°K @12V, -40mV/°K@24V
244Hz
50V (Uoc on module label)
max. 20 A @ 25°C
1 min
max. 20A @ 25°C
when no charge current
when charge current flowing
10 min
Illuminated graphic LCD
128 x 64 pixel
VA screw, max. 16mm²
25A, internally soldered
0.0 – 0.27V (@ 0 - 20 A)
-25° C ... + 50° C, non-thawing
-25° C ... + 80° C
Relay, bistable
IP 22
300 g