Significance of the data output:
Battery 1 = Present battery voltage on terminal B1
Battery 2 = Present battery voltage on terminal B2
ICharge
= Present charge current
ISolar
= Present current generated by the modules
IOut
= Present load current
Significance of the parameter displays:
Mode Output:
Sets the type of use of the output terminal. 4 functions are available:
AUTO
LAMP
ON
OFF
When AUTO is selected, the controller automatically witches off the
consumers if the battery is discharged too much. If the battery voltage
increases again, the consumers will be switched on again
automatically.
When LAMP is selected, the controller presumes that a small light (e.g.
as orientation light) is connected to the output terminal. This light will
then be switched on every night, as soon as the module does no
longer supply charge current, and switched off again at dawn. The
total discharge protection remains active.
When ON or OFF is selected, the status of the terminal remains
permanently in the selected position. In the case of ON the voltage of
battery 1 is applied to the terminal.
(this value may be greater than ICharge when the
charge controller reduces the charge current to prevent
a battery overcharge)