5 |
Display functions FOX-360
WARNING: Selecting the position ON deactivates any protection
[ ! ]
against total discharge of battery 1.
Capacity Usage:
The capacity utilization of battery 1 can be set in 5 % increments.
The value of 80 % means that the consumers connected to the output
terminal are only switched off when there is only 20 % of residual
capacity left in battery 1.
A value greater than 80 % cannot be set.
If the output function is changed, the capacity use will be reset to the
default value defined for this function.
Default values:
Function: AUTO = 80 % (10,8 V)
Function: LAMP = 50 % (11,3 V)
If the output function is changed, the capacity use will be reset to the
default value defined for this function.
Battery Type:
In order to best adapt the charge characteristic curve and the cut-off
voltage to the connected battery type, the type can be set using this
function.
The following options are available:
AGM
Gel
Lead-acid
Default setting: AGM
27
(End-of-charge voltage 14,2 V)
(End-of-charge voltage 14,3 V)
(End-of-charge voltage 14,4 V)