The charge controller can be operated in parallel to other charging
devices (such as alternators, generators, fuel cells). Modules of all
manufacturers can be connected to the controller.
With series connection, the off-load voltage of the solar modules and/or
the solar system must be smaller than 50 V.
In the case of the FOX-360 the terminals B1(-), B2(-) and Output are
directly connected with each other via the negative conductor.
Therefore it is important when connecting B1 and B2 that both batteries
are connected to each other at the negative pole with a large wire cross
section.
The smallest permissible line cross-section is 4 sq mm (~ AWG12); the
battery lines must be provided with a 20A fuse directly at the plus poles
of the batteries.
By means of the keyboard, different presentations can be selected in
the display and various basic parameters of the controller may be
changed and stored.
Current battery voltages may also be additionally presented as a
graphic in bar form.