including correct interpretation of the drawings, signs and
pictograms;
• sufficient technical knowledge for safely performing his
duties as specified in the manual;
• knowledge of the regulations on work hygiene and safety.
In case of a significant anomaly (e. g. short circuits, wires
coming out of the terminal block, motor breakdowns, worn
F
TECHNICAL DATA
F.1
Main technical characteristics
Model
Supply voltage:
Convertible to:
Frequency
Max. power
Water supply pressure
Water supply temperature
Boiler heating elements
Tank heating elements
Water supply hardness
Electric conductivity of water
Concentration of chlorides in
water
Rinse cycle water
consumption
Boiler capacity
Tank capacity
Standard cycle time with
water supply at 50℃ [122℉].
2
Legal noise level Leq
Protection rating
Power supply cable
1.
Standard cycle time may vary should the inlet water temperature and/or the boiler heating elements be different from that indicated above.
2.
The noise emission values have been obtained according to EN ISO 11204.
G
PRODUCT DESCRIPTION
G.1
General description
The appliance is suitable for washing glasses, cups, cutlery.
Under no circumstances it can be used for other applications
or ways not provided for in this manual.
This equipment has been created in order to ensure a better
work environment and cost efficiency.
These appliances are used in restaurants, cafeterias, cooking
centers and large institutions. The special dish racks, that can
be equipped with various inserts, offer practical and easy use
for obtaining excellent washing results.
The electronic system enables complete supervision of the
washing process. The control panel also has a display that
shows the operating parameters and signals any faults.
EXLIG
ZXLIG
380-415V 3N~
230V 3~ - 230V 1N~
50 Hz
6.68 kW
1 bar [100 kPa] - 6 bar [600 kPa]
℃
10 - 50
[℉]
[50 - 122]
kW
6
kW
2.4
°f/°d/°e
20/11/14 max
μS/cm
< 400
ppm
< 20
l
2.2
l
5.5
l
22
sec.
120 - 240 - 360 - 540
1
dB(A)
LpA: 63dB - KpA: 1.5dB
IP23
H07RN-F
electrical cable sheathing, etc.) the operator for normal
machine use must:
• immediately deactivate the machine by turning the switch
disconnector to "O" or operating the main emergency switch
on the equipment;
• close the machine water supply by shutting off the water.
EXLIWG
ZXLIWG
380-415V 3N~
230V 3~ - 230V 1N~
50 Hz
6.68 kW
1 bar [100 kPa] - 6 bar [600 kPa]
10 - 50
[50 - 122]
6
2.4
35/19.5/24.5 max
< 400
< 20
2.2
5.5
22
120 - 240 - 360 - 540
LpA: 63dB - KpA: 1.5dB
IP23
H07RN-F
G.2
Machine overview
Door
Control panel
2
ENGLISH
11