Warming Drawer Installation
Integrated Drawer Front
INSTALL RECESSED CLEATS AND PLATFORM
For an overlay or flush inset application, you will need to
install a recessed platform and cleats into the opening.
Refer to the chart for specifications. Proper recess of the
platform and cleats is critical to the function and esthetics
of the warming drawer installation.
The depth of the platform may increase with the cabinet
depth. Be sure to rigidly mount the platform so that it
can support a minimum of 91 kg. Refer to the illustrations
below.
Mounting holes will need to be drilled in the back of the
drawer front panel. Holes should be drilled on site to
ensure proper fit and gaps are achieved. A drilling
template is provide with the integrated drawer front.
IMPORTANT NOTE: Be sure to finish the inside lip of the
opening and the front face of the platform and cleats.
These areas may be visible when the drawer is open.
IMPORTANT NOTE: Be aware of the location of the
mounting holes on the warming drawer frame to make
sure screws used to attach the cleats do not interfere with
screw holes for mounting the warming drawer.
TOP CLEAT
TOP CLEAT
PLATFORM
PLATFORM
SIDE CLEAT
SIDE CLEAT
CLEATS AND PLATFORM
CLEATS AND PLATFORM
RECESSED 5 mm
RECESSED 5 mm
CABINETRY
PLUS THICKNESS
CABINETRY
OPENING
OF DECORATIVE PANEL
OPENING
Overlay application.
Flush inset application.
Integrated Drawer Front
DRAWER FRONT
W
H
Overlay Panel (min)
746 mm
260 mm
Flush Inset Panel
746 mm
254 mm
CLEATS AND PLATFORM
W
H
Top Cleat
759 mm
16 mm
Side Cleats
13 mm
232 mm
Platform
759 mm
19 mm
RECESS CLEATS AND PLATFORM
Overlay
Flush Inset
thickness of custom panel + 5 mm
Electrical Requirements
The electrical supply should be located as shown in the
illustration for your specific installation on the previous
page. Follow local codes and ordinances when installing
the receptacle. A separate circuit, servicing only this appli-
ance is required.
If two warming drawers are installed side by side, they can
operate from the same electrical outlet. A 30 amp circuit
breaker is required for this installation.
IMPORTANT NOTE: When installed outdoors, a ground
fault circuit interrupter (GFCI) is required to reduce the risk
of electrical shock.
Electrical Requirements
Power Supply
220-240 V AC, 50/60 Hz
Circuit Breaker
15 or 20 amp
Receptacle
3-prong grounding-type
IMPORTANT NOTE: Connection of this appliance should
be through a fused connection unit or a suitable isolator,
which complies with national and local safety regulations.
The on /off switch should be easily accessible after the
appliance has been installed. If the switch is not acces-
sible after installation (depending on country) an additional
means of disconnection must be provided for all poles of
the power supply. When switched off there must be an all
pole contact gap of 3 mm in the isolator switch. This 3
mm contact disconnect gap must apply to any isolator
switch, fuses and/or relays according to EN60335.
Anti-Tip Block
INSTALL ANTI-TIP BLOCKING
D
Install a 51 mm x 51 mm or 51 mm x 102 mm anti-tip
19 mm
block against the rear cabinet wall. When the warming
19 mm
drawer is installed below a built-in oven, you may use a
D
22 mm thick platform to allow the warming drawer trim
51 mm
and the oven trim to meet. The platform will act as an
51 mm
anti-tip device for the warming drawer.
603 mm
5 mm
An anti-tip block or platform must be installed to
prevent the warming drawer from tipping forward while
opened when loaded. Failure to do so could result in
personal injury and damage to the cabinet.
Install the Warming Drawer
Unpack the warming drawer on a flat surface. Remove all
packaging materials from inside the warming drawer. Do
not discard the package containing the two wood screws
needed for installation.
Turn power off to the electrical outlet.
Slide the left corner of the warming drawer into the
opening. If the electrical outlet is installed inside the
opening, plug the power cord into the outlet. The excess
cord should be coiled behind or beside the unit. If the
outlet is located in an adjacent cabinet, thread the power
cord through the hole in the cabinet wall. Push the drawer
back into the opening until the trim meets the cabinet
front. Make sure the power cord does not get trapped
under the warming drawer.
IMPORTANT NOTE: Do not lift up on the handle to push
the drawer into place.
Open the warming drawer to its full extension. Drill pilot
holes in each side hole, located toward the front on each
side of the warming drawer. Install the wood screws
provided with the unit. Refer to the illustration below.
Turn power back on to the electrical outlet.
LOCATION OF
SIDE HOLE
Location of side hole.