Installation Considerations - Wolf ICBWWD30 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installation Considerations

Installation Considerations
MODEL ICBWWD30
Model ICBWWD30 must be installed with a Wolf stain-
less steel or integrated drawer front. Specific installa-
tion instructions are included with the drawer front.
The warming drawer platform must be able to support
91 kg.
The warming drawer platform must be a minimum of
25 mm above the toe kick to allow for the overlap of
the warming drawer trim.
For undercounter installations, 597 mm from the
bottom of the warming drawer opening to the floor
is typical.
COMBINATION INSTALLATIONS
Model ICBWWD30 may be installed in combination
with a Wolf built-in oven and/or microwave. Additional
clearance between warming drawer and oven openings
may be required. To allow the warming drawer trim and
the oven trim to meet, a 22 mm platform may be used
to separate the two openings. This will act as the
support platform for the oven and the anti-tip device
for the warming drawer. An anti-tip block may be
installed at the rear of the cabinet in place of the
platform. If the warming drawer is installed above an
oven, a 22 mm platform is required to allow for clear-
ance of overlaps.
Model ICBWWD30 may be installed below a Wolf
cooktop or sealed burner rangetop. Allow enough
room for gas and electrical connections for the
cooktop.
Model ICBWWD30 may be installed next to or above
another Wolf warming drawer.
IMPORTANT NOTE: For combination installations, refer
to installation instructions provided with the other Wolf
products for additional specifications.
ICBWWD30 Drawer Front Options
IMPORTANT NOTE: Model ICBWWD30 must be installed
with a Wolf stainless steel or integrated drawer front.
An E Series or Pro drawer front with handle is recom-
mended. These front panels are designed on the E Series
front panel platform and are available with a tubular,
curved or pro handle.
The Pro drawer fronts with pro handle are designed to be
installed below a sealed burner rangetop so the panel
aligns properly with the front of the rangetop.
For information on integrated door front, refer to page 8.
OVERALL DIMENSIONS
A
264
mm
19 mm
759 mm
B
578 mm
911 mm
OR
718 mm
19 mm
546 mm
B
Drawer Front Panel and Handle
L SERIES
A
Tubular Handle
22 mm
E SERIES
A
Curved Handle
29 mm
Tubular Handle
29 mm
PRO SERIES
A
25 mm Thick / Pro Handle
29 mm
51 mm Thick / Pro Handle
54 mm
Dimensions may vary ± 3 mm.
6
229
mm
B
89 mm
B
70 mm
89 mm
B
89 mm
114 mm

Publicité

Table des Matières
loading