• With all applications using "Single Mode" (6.4.1) or one of the "Combined Modes"
(6.4.3), both presets always refer to the actual value appearing in display. Please be
aware that toggling the display will affect the outputs
• Use of "Dual Mode" (6.4.2) automatically attaches Preset 1 to input channel A and
Preset 2 to input channel B, independent on which of the values is actually in
display
• When Preset 1 is used to monitor a minimum value with setting "LE", and Preset
2 is used to monitor a maximum value with setting "GE", then output 1 will
operate with an Automatic Startup-Inhibit, i.e. it will become enabled only after
the measuring value has crossed the minimum setting the first time.
Where no startup-Inhibit is desired, please use Preset 1 for Maximum and
Preset 2 for minimum control.
6.573.011.E00_7b_e.doc / Sep-08
Page 20 / 28