6.4.4. Additional settings for use of the Preselections
Basic settings for Presets:
The basic setup menu provides the following additional parameters which are relevant for the
operation of the presets and outputs only:
Menu Text
Output 1 switching characteristics
Output 2 switching characteristics
Switching Hysteresis 1
Programmable Hysteresis for output 1
Switching Hysteresis 2
Programmable Hysteresis for output 2
*) Serves to generate an anticipation signal at a fixed distance to the preset 1 signal. The anticipation
automatically follows the setting of preset 1.
6.573.011.E00_7b_e.doc / Sep-08
Greater/Equal:
Output is statically active with display
greater or equal Preset.
Lower/Equal:
Output is statically active with display
lower or equal Preset.
Greater/Equal:
Output is dynamically active with
display greater or equal Preset.
(timed output impulse)
Lower/Equal:
Output is dynamically active with
display lower or equal Preset.
(timed output impulse)
See above
See above
See above
See above
Output is statically active when the
display reaches the value of Preset 1 –
Preset 2 *)
Output is dynamically active when the
display reaches the value of Preset 1 –
Preset 2 *)
Setting Range
Default
0 ... 99999
0 ... 99999
Page 18 / 28
0
0