2.8 Changes to the device. Any intended change to the equipment must be authorized in writing by Manufacturas
Rocal, S.A. We also recommend using only original spare parts or parts recommended by Manufacturas Rocal, S.A.
3. INSTALLATION
3.1 Installation process. To proceed with the installation, follow the steps outlined in Section III of the ANNEXED
document. WARNING: The second piece of the deflector plate should be adjust or remove in case of draught defect, to
procede follow the steps:
opening follow the steps shown at images "D.15" to "D.22"
. USE AND OPERATION
4
4.1 Fuels authorized by the manufacturer. The appliance should not be used as an incinerator and the use of fuels
other than those authorized by the manufacturer are prohibited, including lighting liquids or gels. Only natural wood logs
are authorized as fuel and it is not advisable to use resinous woods.
CAUTION:
- The maximum load allowed by the manufacturer, the measurements of the logs and the
height of the reload must be respected.
- Do not touch or manipulate any part of the appliance when in operation without a
protection glove.
4.2 Pilot fire lighting. For a reasonable period of time, approximately 24 hours, it must not exceed 50% of the Maximum
load allowed by the manufacturer. Before lighting the fire, ensure that nothing delivered with the equipment has stayed
inside (such as gloves, spray paint ...)
4.3. Combustion control. The appliance has mechanisms to regulate combustion.
4.3.1. Primary register. The primary register is used to control the air entering the combustion chamber through the
base of the fire, through the fire grate. The primary register should be used mainly for lighting and, if necessary, to aid
combustion. To locate the register control handle and to know how to use it see picture "D.2" on page 9 of the ANNEXED
document. If fuel is low quality you can adjust the path of the primary register following the passos: "D.26" to "D.29". If
the problem persists adjust the air entry by fire grate following the steps "D.26" and "D.30".
4.3.2. Secondary register. The secondary register is used to control the air entering the combustion chamber from the
top. The secondary register is used as combustion intensity adjustment. To locate the register control handle and to
know how to use it see picture "D.3" on page 9 of the ANNEXED document. If fuel is low quality you can adjust the path
of the secondary register following the passos: "D.26" to "D.29".
CAUTION:
The positions of the registers shown in the technical specifications table are trial positions;
in any case, these positions must be adapted according to the draught of the duct and fuel
quality.
4.4 Fire lighting. To light the fire, use suitable materials for this purpose, such as heat pads, paper, dry and thin
branches. DO NOT USE GASOLINE, SOLVENTS OR ALCOHOL. To see the correct position see picture "C.5" on page
9 of the ANNEXED document, then light the fire using a suitable material. Once the fire is lit keep the door and the
registers open for a reasonable time to prevent condensation on the door. When the apparatus is hot enough close the
door, adjust the primary register to avoid excessive combustion and control the intensity of fire by the child record.
IMPORTANT: -The interior vermiculite parts SHOULD NOT RECEIVE IMPACTS when refueling is
performed.
If any of these parts crack, but is properly set in its place, THE PROPER OPERATION OF
THE APPLIANCE SHALL NOT BE ALTERED AND THERE IS NO POTENTIAL RISK. The
equipment can be used normally. These cracks do not entail any manufacturing defect so
they do not fall under guarantee.
4.5 Loading and reloading of fuel. Do not exceed the maximum allowed load or reload. (See Table of Technical
specifications).
To adjust the door closing follow the steps "D.13" and "D.14". To change door
"D.9" to "D.12".
16