Rocal ARc 50 Manuel D'installation Et Fonctionnement page 15

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
7. Exterior air inlet kit. (Exterior air inlet connector, connector support, tubular joint, metallic anchor, screws and
nuts)
8. Tool for handling registers and opening door.
9. Bag with screws.
10. Envelope with 3 documents: specifications, installation and operation manual, and Guarantee sheet.
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE
SHALL EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not,
you will need a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please
consult a specialist.
2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside
in observation of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified
by a professional and must also observe the relevant national regulations. This Flue liner should not be shared
with other devices (see Table 1.1 Technical specifications).
2.3 Type of appliance "Vermiculite" home plate at the bottom, sides and baffle plate, fire grate, ash pan and ventilation
set incorporated. The fireplace comes ready to install. Provision should be made from inside an output for the electric
cable. All the inner can be removed if desired, for easier transportation and installation.
2.4. Insulating procedures.
2.4.1. Apparatus insulation. The fireplace must be insulated with insulation panels (Type A-1, EN13501-1) on its sides,
back and upper part.
2.4.2 Fireplace room insulation. It is also convenient to use insulation panels on the inner walls of the fireplace (Type
A-1, EN13501-1).
2.5. Safety distances.
2.5.1. Inner fireplace room safety distances. You must be respected the values described in 1.1 Technical
characteristics.
2.5.2. Outer fireplace safety distances. Anything fragile or flammable (textile, electronics, wood, paper wall, glass,
chalk...) should be separated of the appliance and respected the safety distances described in 1.1 Technical
characteristics.
We must take special care in those fireplaces with wooden shelves or similar: we must prevent and avoid the possibility
of hot air that expels the device falls directly on the wood, in these cases, flammable items should be properly insulated.
2.6 Fireplace room. Fireplace room must be built with non-combustible materials and should not rest on the apparatus
and the points of contact (such as the front frame). Inside should not contain flammable or fragile materials such as
wood, wallpaper, glass, chalk paper, etc.).
.
2.7. Ventilation
It is imperative that the niche where the appliance is installed ventilation available.
2.7.1. Fireplace room ventilation. The appliance must be provided with an air outlet or inlet diffusers for sufficient air
flow as described in Technical characteristics
2.7.2. Hot air outlet options:
- WITHOUT air outlet pipes connection. Image III-1 on page 3 of the ANNEXED document. NO used the
upper air outlet, the fireplace room air is output from the front of it
- WITH air outlet pipes connection. Image III-2 on page 3 of the ANNEXED document. If you want you can
drive the air from fireplace room to the top or adjoining room.
2.7.3 Air supply. Air should be provided to the room where the appliance is installed. This is especially relevant when
outside air is not used and also when the door is opened for reloading with logs. This entry cannot be less than 225
cm2. Also note the simultaneous operation with other ventilation devices and / or heating such as exhaust fans, heat
pumps, etc. In these cases, the extraction must be compensated with a corresponding air entry from outside.
15

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arc 70Arc 70aArc 70cArc 80Arc 100

Table des Matières