Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• The product is not designed to be used with steam baths!
Thermostatic mixer in conjunction with combination boil-
ers
• If fitting a hand shower remove the water limiter from the shower.
• If the continuous water heater causes any problems, or you have different water
pressures you must install a water limiter to the cold supply, (ordered separate-
ly,article number 97510000).
• Thermostatic mixer Shower: When using the Ecostat with combination boilers,
the Ecostop safety set (95042000) has to be removed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Centre distance:
Connections G 1/2:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 8)
The desired maximum temperature for example max. 42º C can be pre-set thanks
to the safety function.
Fault
Insufficient water
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
Spout temperature does not correspond with
temperature set
Temperature regulation not possible
Shower drips continuously
Instantaneous heater didn't work with thermostat
4
English
After the installation, the output temperature of the thermostat must be checked. A
correction is necessary if the temperature measured at the output differs from the
temperature set on the thermostat.
• The check valves must be checked regularly according to EN 806-5 in
• To guarantee the smooth running of the thermostat, it is necessary from time to
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
150±12 mm
cold right - hot left
70°C / 4 min
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Dirt or sedimentation on valve seat, shut-off unit
damaged
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't removed
- Ecostop safety set removed.
Assembly (see page 7)
Adjustment (see page 8)
ECOSTOP (see page 9)
Maintenance (see page 9)
accordance with national or regional regulations (at least once a year).
time to turn the thermostat from total hot to total cold.
Dimensions (see page 12)
Flow diagram (see page 12)
Shower outlet
Tub outlet
Spare parts (see page 11)
Cleaning (see page 10)
Operation (see page 13)
Test certificate (see page 14)
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-ther-
mo cartridge
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 60 ºC
- Exchange thermo cartridge
- Clean or exchange shut-off unit
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
- Remove Ecostop safety set (95042000)