Diagnostics And Installation - THOMSON SMART 762 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
C - iNSTALLATiON
1
2
3
4
• Thread the wires into the space provided for
this purpose.
• Connect the connection terminals, making
sure to follow the colour coding precisely.
12
EN
1
2
3
4
1
2
3
4
1
2
3
4
Colour video interCom 18Cm

4 -DIAGNOSTICS AND INSTALLATION

• Once the connections have been completed,
before installing the monitor, all the indicator
lights on the intelligent bracket must be blue:
Indicator light for connecting an additional
monitor
:
R ed = Connection error
B lue = Connection OK or monitor not present
Power supply indicator light
R ed = Power supply > 16V
Blue = Power supply < 16V OK
Intercom panel connection indicator light :
Red = Reverse polarity
Blue = Wiring OK
Intercom panel connection indicator light
: R ed = intercom panel not connected (wire
unplugged or cut)*
Blue = connection OK
* This is completely normal if the monitor is used
as an additional monitor on an existing installation
and no intercom panel is directly connected to it
• If all the indicator lights on the intelligent
bracket are blue (with possible exception to
the one from the intercom panel, see below),
place the monitor in its compartment. If not,
check installation.