4 - DIAGNOSTICS AND INSTALLATION

• Once the connections have been made
and before installing the monitor, check the
intelligent bracket status:
Indicator light for connecting an additional
monitor
:
R ed = Connection error
B lue = Connection OK or monitor not present
Power supply indicator light
R ed = Power supply > 16V
Blue = Power supply < 16V OK
Intercom panel connection indicator light :
R ed = Reverse polarity
Blue = Wiring OK
Intercom panel connection indicator light
: Red = intercom panel not connected (wire
unplugged or cut)*
Blue = connection OK
* This is completely normal if the monitor is used
as an additional monitor on an existing installation
and no intercom panel is directly connected to it
• If all the indicator lights on the intelligent
bracket are blue (with possible exception to the
one from the intercom panel, see below), place
the monitor in its compartment. If not, check
installation.
:
C - iNSTALLATiON