Assembly and operating instructions for an
exhaust air controller Model AS-6030.3
(radio version)
Thank you for purchasing the PROTECTOR
AS-6030.3 Exhaust Air Controller.
INTRODUCTION
This device can be used as an exhaust air control device,
as an aid to monitor fresh air supply when commissioning
an exhaust air device (fume extractor hood, fan etc...).This
cannot replace self-monitoring to ensure fresh air supply,
but it can be supportive. When the furnace is active (hot
stovepipe) this device only activates the exhaust air system
in the event of pressure equalisation when a window or door
is opened. The additional fresh air streaming in can thus be
drawn in from the outside.
GENERAL
This device can be used as an exhaust air control device,
as an aid to monitor fresh air supply when commissioning
an exhaust air device (fume extractor hood, fan etc...).This
cannot replace self-monitoring to ensure fresh air supply,
but it can be supportive. When the furnace is active (hot
stovepipe) this device only activates the exhaust air system
in the event of pressure equalisation when a window or door
is opened. The additional fresh air streaming in can thus be
drawn in from the outside.
ATTENTION: When using this device for exhaust air control,
the shutter must be open to ensure adequate inflow of
fresh air!
KEY
1 AS-6030.3 Receiver
2 Code button Test/Coding
3 LED Status
4 Window transmitter
5 LED Status
6 Magnet for window transmitter
U Washers
9 Furnace transmitter
10 Thermo-sensor
11 Status button Furnace transmitter
12 LED Furnace hot (red)
13 LED Furnace cold (green)
14 Battery compartment lid
B Battery control LED
K Sensor cable
15. Exhaust pipe
16. Feedthrough hole (4 mm)
17. Fastening holes (2 mm)
H Holder
USE OF ADDITIONAL TRANSMITTERS
The device can be expanded with one window and one
furnace transmitter, whereby the extractor hood is no longer
bound to an individual window or furnace. Each individual
window transmitter can enable the exhaust unit and each
individual furnace transmitter can disable the exhaust unit.
17
ENGLISH | AS-6030