Télécharger Imprimer la page

Pentair 620400Z Guide D'installation page 3

5g pour piscine avec un joint neuf

Publicité

Les langues disponibles

Les langues disponibles

Installing the IntelliBrite
1.
Turn off main electrical switch or circuit breaker, as well as the switch which
operates the IntelliBrite light itself. Note: DO NOT
pool water. Service the light on the deck.
2.
REMOVE THE INTELLIBRITE 5G POOL LIGHT ASSEMBLY: Remove the special
bronze pilot screw at top of face ring. Remove the IntelliBrite light assembly from
the niche and place it on the deck. Note: It is not necessary to drain down the
pool.
3.
Unwind the cord from the base of the light housing.
4.
Place a cloth on the ground to
protect the lens. Turn the light
over so the lens is resting on
the cloth. Using a 1/4 in (0.64
cm) nut driver and a #3 Phillips
screwdriver, remove the nut from
the Uni-Tension Wire Clamp.
Place the nut aside for
reinstallation.
5.
Remove the face ring and
wire clamp from the light
housing. Discard the
Uni-Tension Wire Clamp.
6.
With the light resting on
its base, carefully pry off
the gasket to remove the
lens. Set the lens aside for
installation later. Discard
the gasket.
Note: A NEW LENS
GASKET (P/N 620400Z)
AND UNI-TENSION WIRE
CLAMP MUST BE USED
EACH TIME THE LIGHT IS
REASSEMBLED.
Continue to next page.
Gasket and Uni-Tension Wire Clamp
INTELLIBRITE
®
5G Pool Light Fixture
service the light while in the
5G Pool and Spa Lights Gasket Kit Installation Guide
®
2
Gasket
Lens
Uni-Tension
Wire Clamp:
Remove nut
and screw,
Save nut for
reinstallation.
Uni-tension
wire clamp
Face ring

Publicité