The charging booster can be adapted to different
battery types via DIP switches (see chapter "Setting
the charging program" on page 21).
The temperature sensor monitors the battery tem-
perature during the charging process (see chapter
"Temperature sensor" on page 18).
The charging booster is equipped with a remov-
able display panel for remote control.
The charging booster offers the following func-
tions:
• Microprocessor-controlled, temperature-com-
pensated IU0U charging programs for various
battery types
• Auxiliary charging output for the starting battery
• Buffer operation: Compliance with the charging
characteristics even when the battery is charged
with consumers connected
• On-board mains suppression filter: Ensures par-
allel operation of the charging booster with
other charging sources, for example mains sup-
ply chargers, solar systems or generators
• Automatic compensation of voltage loss caused
by the charging cable length (house battery)
The charging booster has the following protective
mechanisms:
• High voltage protection
• Low voltage protection
• High temperature protection
• Low temperature protection (only LiFePO4 bat-
teries)
• Battery overcharge protection
• Reverse current protection
• Protection against short circuit
• Reverse polarity protection (only for house bat-
tery connection)
16
Description of the device
Item in
fig. 1,
Designation
page 3
1
Display panel
2
DIP switches battery type and functional
settings
3
DIP switch charging current
4
Rubber feet
5
Connections and controls
6
Temperature sensor
Connections and controls
Item in
fig. 2,
Designation
page 3
1
START–
2
START+
3
Sense START
4
D+/ Kl. 15
5
EBL Start/IN
6
BORD–
7
BORD+
4445103799
Description
Connection to negative
pole of 12 V/ 24 V starting
battery
Connection to positive
pole of 12 V/ 24 V starting
battery
Input for sense cable to
measure and control the
charging voltage at the
starting battery
Input for D+ signal of the
alternator or ignition lock
signal (terminal 15)
Input for sense cable to
display the charging volt-
age at the starting battery
Connection to negative
pole of 12 V/ 24 V house
battery
Connection to positive
pole of 12 V/ 24 V house
battery