FB4 units
60W versions:
Ex d IIC T4 (-55°C to +70°C)
Ex td IIIC T135°C (-55°C to +70°C) Db IP6x
Ex d IIC T5 (-55°C to +30°C)
Ex td IIIC T100°C (-55°C to +30°C) Db IP6x
100W versions:
MK6 terminals fitted:
Ex d IIC T3 (-55°C to +55°C)
Ex td IIIC T185°C (-55°C to +55°C) Db IP6x
SAK or MK6 terminals fitted
Ex d IIC T3 (-55°C to +30°C)
Ex td IIIC T160°C (-55°C to +30°C) Db IP6x
FL4 units
13W Versions:
Ex d IIC T4 (-20°C to +85°C)
Ex td IIIC T135°C (-20°C to +85°C) Db IP6x
Ex d IIC T5 (-20°C to +55°C)
Ex td IIIC T100°C (-20°C to +55°C) Db IP6x
Ex d IIC T6 (-20°C to +40°C)
Ex td IIIC T85°C (-20°C to +40°C) Db IP6x
26W Versions:
Ex d IIC T4 (-20°C to +85°C)
Ex td IIIC T135°C (-20°C to +85°C) Db IP6x
Ex d IIC T5 (-20°C to +55°C)
Ex td IIIC T100°C (-20°C to +55°C) Db IP6x
Ex d IIC T6 (-20°C to +40°C)
Ex td IIIC T85°C (-20°C to +40°C) Db IP6x
39W Versions:
Ex d IIC T4 (-20°C to +70°C)
Ex td IIIC T135°C (-20°C to +70°C) Db IP6x
Ex d IIC T5 (-20°C to +40°C)
Ex td IIIC T100°C (-20°C to +40°C) Db IP6x
For both the FB4 and FL4 units, the ATEX certificate and product label carry the ATEX group and category
marking:
II 2 GD
Where:
Signifies compliance with ATEX
II
Signifies suitability for use in surface industries
12/10