Display
aj
sine wave
inverter solar
10
on – AC out present 230V / 120V ac
off – AC out not present, the solar charge controller (s
models) remains in operation even if the inverter is off
blink : _ _ _ _ _ no load (standby)
__ __ __ __ __ alarm (automatic restart)
manual ON/OFF button
solar* PV (s models)
on – charge
off – night
blink – floating
aj
sine wave
inverter solar
BLO, Battery Life Optimizer
on – BLO is activated
blink – LVD (Low Voltage Disconnection)
LED
12V
24V
48V
on
10.6
21
42
1x
11
22
44
2x
11.4
22.8
45.6
3x
11.6
23.2
47.2
4x
11.8
23.6
47.2
5x
12
24
48
6x
12.2
24.4
48.8
Standby
2W (1-20W)
11