SECTION 3: INSTALLATION
WATER COOLER INSTALLATION INSTRUCTIONS, MODELS: KEPWSBF
SECTION 3: CONNECTING THE WATER LINE
DRINKING FOUNTAIN
A. DRILLING HOLE IN THE TOP FOR WATER LINE CONNECTION
1. Disconnect power by UNPLUGGING unit. It might be necessary to remove the front panel to get access to the power.
2. Turn OFF water supply to the unit. It might be necessary to remove the front panel to access the water stop valve.
B. RETROFIT or FOUNTAIN/FRAME - PRESSURIZED
3. Place hole template onto cooler top so it is aligned with the left side of unit and wall. (TEMPLATE FOUND ON PAGE 17)
(for units not pre-plumbed and pre-drilled)
4. Mark hole location.
a) Disconnect power by UNPLUGGING unit. It might be necessary to remove the front panel to get access to the power.
5. Remove top from unit. (Figure 1)
b) Turn OFF water supply to the unit. It might be necessary to remove the front panel to access the water stop valve.
6. Using a 3/8 drill bit, drill a hole through top.
c) Place hole template onto cooler top so it is aligned with the left side of unit and wall. SEE NEXT PAGE FOR TEMPLATE.
7. Install snap bushing into hole to protect tubing from being cut. (Figure 2)
d) Mark hole location.
Mark hole location
Template
e) Remove top from unit. (Figure 1)
B. CONNECTING THE WATER LINE
f) Using a 3/8 drill bit, drill a hole through top.
If the cooling tank is non-pressurized, then go to the "Pressurizing the cooling tank" addendum section. Otherwise, proceed to
g) Install snap bushing into hole to protect tubing from being cut. (Figure 2)
STEP 1 next page. Non-pressurized units are single units made since December of 2009. Refer to the schematic below to identify
the system that you have.
Supply
Water
0112
036865-003
02/20 | 2000102863_KEPAC-SBF
Figure 1
Remove top from cooler by
removing six #15 torx head
screws on sides of top.
Water
valve/regulator
NON-PRESSURIZED
COOLING TANK
Drill
Supply
Water
PRESSURIZED
COOLING TANK
Figure 2
Install Bushing
Water
valve/regulator
5
10

Publicité