6.1) ALARM/ASSISTANCE
When the appliance is in the sleep mode it highlights the GSM field in those models that have the function and the writing CONNECTION in
case of alarm. Following an electric control o via radio on one of the 4 messages, the appliance calls all the telephone numbers in the book
combined to an activated message. This occurs on phone net or GSM according to the models and the set priority programming.
When the called number answers, the message is repeated twice. If the called number is busy or absent the call is repeated after 3 minutes and
so on for other two times. In case of programming without line control, the message is repeated 4 times (see 8.3).
To interrupt the next calls to other users press the key # on your telephone after the end of message beep: the appliance will stop the calls. In
order to listen to the environment noises through the appliance press the key ∗ on your telephone after the end of message beep. However the
relative SMS message is sent to all the numbers in the telephone book combined to the activated message.
6.2 LOAD CONTROL VIA TELEPHONE (ONLY 5150 – 5152 MODELS)
Call to the GSM module in board: it is always activated to answer to answer coming-in calls: it is necessary to listen to the instruction
message, wait for the and then type in the user's code followed by # (if the caller has a direct access it is not necessary to type in USER CODE)
Controls of the possible executions, with sound signal for every pressed key:
- type in ∗ to access the "handsfree" function that allows to listen and dialog.
- type in 1 ∗ 1 # to activate the relay 1, that is deactivated typing in 1 ∗ 0 #
- type in 2 ∗ 1 # to activate the relay 1, that is deactivated typing in 2 ∗ 0 #
- type in 1 (2) # to control the state of the relay 1 (2): the appliance answers with 3 beeps if the relay is activated, with one if the relay is
deactivated.
6.3 ACCESS TO THE HISTORY FILES (EVENTS MEMORY)
The access to the history file is made by typing in the installer/user's code followed by the ↓ key. The history file has the date, called name and
the call's outcome (OK: call had a positive outcome, NO: no reply, OC: line busy) for the last 200 calls, highlighting any absence of GSM field,
lack of traditional line, occurred modification from remote etc. The following is also reported: the indication of the going-out telephone call (←) or
coming-in telephone call (→) and the indication of the type of call or SMS (S) or Vocal (V).
Return to the stand-by mode is made through the ESC key, or automatically after 1 minute without operations.
6.4 REMOTE CHANGING OF TELEPHONE NUMBERS (ONLY MODELS 5150 - 5152)
By means of an SMS from a remote GSM it is possible to change the telephones numbers stored in the phone book; the number of the remote
phone must be memorized on the system with the direct access function "Y" (yes). Compile the message as follows (bold):
A333555666 (old number to replace) A333666888 (new number to insert)
The appliance memorizes the variation and sends a confirm SMS: CHANGE MADE *333666888*
6.6 CALL BLOCK ON APPLIANCE: type in the user/installer's code followed by "CANC" the coming-in calls are blocked.
6.7 REQUEST FOR REMAINING SIM CREDIT (ONLY 5150 - 5152)
Pressing the key ↵ for 2 seconds the automatic call to the provider is made for information on the remaining credit on the SIM that is listened
directly on the appliance.
7) OPERATING
Install every telephone transmitter opportunely hidden where used in alarm systems. It is necessary to verify the presence of a GSM field in the
models with this function before fixing the appliance to the wall, placing another mobile phone that uses the same provider in the exact place
where the appliance will be fixed.
SMS enabling: for the models with GSM it is necessary to eliminate the PIN code or replace it with the numbers 1,2,3,4; to enable the SIM
before using it in the appliances and assess that it has a minimum residual credit: a non-validated SIM, out of order or missing does not allow ur
the appliance to function. Attention! Introduce the SIM to a NON POWER SUPPLIED appliance!
Electric connections: to carry out the electric connections requested by the appliance (see drawing) considering the functioning of the IN-OUT
connections. The control in-outs must be closed on GND (negative) and the transmission are activated by opening. The in-puts of the closed
blocks in POSITIVE block the telephone transmission. The two TAMPER terminals give a closed circuit when the box completely closed (anti-
opening protection of the cover and anti-removal on the bottom). The outlet +OUT is "open collector" and closes by GND for an absence of
GSM field of over 15 minutes (only models 5150-5152).
The relay outputs, present only on models 5150-5152, have a free potential exchange contact in free exchange with a maximum capacity of
500mA at 12V CC. The relay works in a bistable way upon call to the appliance (see
ATTENTION! The appliances 5150-5151-5152 function at 12V CC with backup battery 6V 1,2 Ah The connection with different voltages
and/or the connection with different batteries damages the appliance irreparably, with loss of the guarantee.
The 5590 model runs by 4 alkaline batteries, with autonomy of 1-2 years in consequence of the use.
The mass (GND - pole negative) must be shared by the operating unit (any type) and Vocalphone .
ATTENTION!
8) PROGRAMMING - to be made with a correctly supplied appliance.
The programming of all appliances is simple and a voice guide is available for the various functions to program, therefore we highlight hereafter
only some relevant aspects to particular functions that request appropriate choices.
8.1) KEY FUNCTIONS:
FOR PROGRAMMING
setting of numbers and writing of SMS messages
scrolling of the menu lines and parameters selection
cancellation last selected character space
selection of a menu and/or confirmation of a selection
exit from the selected menu/submenu
cancellation of a carried out programming
SILENTRON - Made I n Italy
FOR WRITING SMS AND TELEPHONES NUMBERS
point
space
asterisk
pause between numbers
COPYRIGHT SILENTRON DFV.PHONEnewXA090616GM